Priming and Operation

SJ35-04 Manual Pump

1.  Fill pump and suction line through the pump discharge or priming port (on flooded suction, simply open 

gate valve to pump).

2.  Ensure outlet nearest to pump is open.
3.  Ensure all valves in suction line are open and switch on pump at power outlet.
4.  Prime should establish almost immediately and a strong flow of water should be evident from 

the outlet. Allow water to flow for 10-20 seconds to expel air then close outlet and switch off 

pump.

5.  If no flow is evident from tap, switch off at power point and repeat from step 1 ensuring there is an 

adequate supply of water available to the pump.

SJ35-04 PC & SJ60-08PC Automatic Water Pressure System

1.  Fill pump and suction line through the pump discharge or priming port (on flooded suction, simply open 

gate valve to pump).

2.  Ensure outlet nearest to pump is open.
3.  Ensure all valves in suction line are open and switch on pump at power outlet. The green ‘Power On’ 

led will light up on the controller. There will be a delay of a few seconds before the pump starts and the 

yellow ‘Pump On’ led will light up.

4.  Prime should establish almost immediately and a strong flow of water should be evident from 

the outlet.  Allow water to flow for 10-20 seconds to expel air then close outlet. Pump will 

switch off shortly after and wait in standby until a drop in pressure initiates a pump start.

5.  If the pump fails to deliver water to the tap, the device will stop the pump. The red led will 

display. Press the Restart button until the red led turns off and water is delivered to the open tap.

6.  If no flow is evident from tap, switch off at power point and repeat from step 1 ensuring there is an 

adequate supply of water available to the pump.

7.  If the pump does not automatically restart on re-opening of tap, consult trouble shooting guide.

Your SJ35-04PC & SJ60-08PC pump is fitted with a controller. This device will automatically stop and start your pump, 

depending on flow demand.

Control Panel

Green led on

Power on

Pump in standby

Yellow led on

Pump on

Pump running

Red led on

Restart

Restart system

Signalling of the working phases and anomalies

Never operate your pump for more than several seconds without discharge flow.

Содержание SJ35-04

Страница 1: ...these instructions on to the operator of this equipment Manual Pressure Pump Model SJ35 04 Automatic Water Pressure System Models SJ35 04PC SJ60 08PC Garden Series Jet Pumps Installation Operating In...

Страница 2: ...P M 2 Suction inlet SJ35 04PC 1 BSP F SJ60 08PC 11 4 BSP F 3 Pump body 4 Motor 5 Priming port and plug 6 Drain port and plug 7 Pressure controller Do not use this pump to pump flammable fluids such as...

Страница 3: ...e installation is subject to electrical power surges or lightning we strongly recommend the use of a suitable surge protection device on ALL electrical equipment Pipe Connections For best performance...

Страница 4: ...st not exceed 45o C or damage caused will not be covered by guarantee Connection of Mains Scheme or Town Water Supply to either Suction or Discharge of Pump Most Water Supply Authorities have strict r...

Страница 5: ...e a delay of a few seconds before the pump starts and the yellow Pump On led will light up 4 Prime should establish almost immediately and a strong flow of water should be evident from the outlet Allo...

Страница 6: ...6 Check valve installed in wrong direction 7 Suction lift too high 8 Leaking air bleed screw 9 Blocked jet or venturi 10 Blocked impeller PUMP STOPS BUT RESTARTS QUICKLY NO FLOW DEMAND AUTO MODELS ON...

Страница 7: ...7 NOTES...

Страница 8: ...ts of similar quality grade and composition where an identical part or component is not available Goods presented for repair may be replaced by refurbished goods of the same type rather than being rep...

Отзывы: