Congratulations on your purchase of a Garden Series quality pressure pump or water pressure system.  All components 

have been designed and manufactured to give trouble free, reliable operation.

Before installing your new pump, please read all instructions carefully as failures caused by incorrect installation or 

operation are not covered by the guarantee. Your Garden Series Jet Pump is designed to handle clean water. The pump 

should not be used for any other purpose without specific referral to Davey. The use of the pump to handle flammable, 

corrosive and other materials of a hazardous nature is specifically excluded.

Model SJ35-04

1. 

Delivery outlet - 1” BSP(F)

2. 

Suction inlet - 1” BSP(F)

3. 

Pump body

4. Motor

5. 

Priming port and plug

6. 

Drain port and plug

Model SJ35-04PC & SJ60-08PC

1. 

Delivery outlet - 1” BSP(M)

2. 

Suction inlet

 

– SJ35-04PC - 1”BSP(F)

 

– SJ60-08PC - 1

1

/

4

”BSP(F)

3. 

Pump body

4. Motor

5. 

Priming port and plug

6. 

Drain port and plug

7. 

Pressure controller

Do not use this pump to pump flammable fluids, such as petrol or diesel fuels.

Choosing a Site

Choose a site with a firm base and as close to the water source as possible with 

correct power supply.  Make sure your pump is always connected to an adequate, 

reliable source of clean water.

Housing your Garden Series Jet Pump

To protect your pump from the weather, make sure the cover provided is water proof, 

frost free and has adequate ventilation.

The pump should be horizontally mounted on a firm base allowing for drainage, to 

avoid damage to flooring etc., that over time may occur from leaking pipe joints or 

pump seals.  Do not mount the pump vertically.

WARNING: Some insects, such as small ants, find electrical devices  attractive for various reasons.  If your pump 

enclosure is susceptible to insect infestation you should implement a suitable pest control plan.

Содержание SJ35-04

Страница 1: ...these instructions on to the operator of this equipment Manual Pressure Pump Model SJ35 04 Automatic Water Pressure System Models SJ35 04PC SJ60 08PC Garden Series Jet Pumps Installation Operating In...

Страница 2: ...P M 2 Suction inlet SJ35 04PC 1 BSP F SJ60 08PC 11 4 BSP F 3 Pump body 4 Motor 5 Priming port and plug 6 Drain port and plug 7 Pressure controller Do not use this pump to pump flammable fluids such as...

Страница 3: ...e installation is subject to electrical power surges or lightning we strongly recommend the use of a suitable surge protection device on ALL electrical equipment Pipe Connections For best performance...

Страница 4: ...st not exceed 45o C or damage caused will not be covered by guarantee Connection of Mains Scheme or Town Water Supply to either Suction or Discharge of Pump Most Water Supply Authorities have strict r...

Страница 5: ...e a delay of a few seconds before the pump starts and the yellow Pump On led will light up 4 Prime should establish almost immediately and a strong flow of water should be evident from the outlet Allo...

Страница 6: ...6 Check valve installed in wrong direction 7 Suction lift too high 8 Leaking air bleed screw 9 Blocked jet or venturi 10 Blocked impeller PUMP STOPS BUT RESTARTS QUICKLY NO FLOW DEMAND AUTO MODELS ON...