10
Step 11:
Always hold UV lamps by their ceramic ends, not by the lamp quartz. Remove
the lamp from its packaging. Again, the use of cotton gloves is recommended. Remove
the lamp key from the lamp’s connector. The lamp key will only be used if the Extra
Smart Controller has been purchased to swap out with the standard controller supplied
on initial purchase. Standard controller does not use the lamp key therefore lamp key
can be discarded. Be careful to not touch the key’s exposed contacts. Insert the UV
lamp into the chamber, being careful not to drop it.
Step 12:
Install the lamp key into the controller. The key always comes packaged with
the lamp and sits on the connector. With the key removed from the lamp, orient it so the
label is upright and facing you. The key will plug into the lamp key port on the right side
of the controller (Figure 10).
Step 13:
Plug the lamp connector into the lamp. Note the keying for proper alignment
(see Figure 9). Insert the lamp connector into the gland nut and turn the connector
approximately ¼ turn to lock the connector to the gland nut as in Figure 11.
Figure 10. Lamp Key
Installation
Figure 11. Lamp Connector
Step 14:
Tighten the captive ground screw to the ground lug on the UV chamber to
ensure proper grounding.
Figure 12. Ground Screw Connection
Step 15:
Your system is now ready to be plugged into the appropriate GFCI 10A GPO
(230V 1phase) protected outlet. Refer to the following section before any water is allowed
to flow through the system.
Figure 9. High Output UV Lamp
Connection