Important for ESR and ESC: The Cell must be installed so that the water flows through the Cell Housing via
the Cell head end in accordance with the arrow on the cell housing. This is to ensure correct operation of
the gas sensor. It is also important to ensure that terminals from the connection leads fit tightly to the cell
terminals.
For ESC50; the cell must be installed as shown on page 4.
PRE - START UP PROCEDURE:
Before operating your ChloroMatic please ensure the following items have been added to your pool:
•
SALT
- Load salt into the pool at the following rates:
• All ChloroMatic Models – 45-60kg per 10,000 litres (4500-6000ppm)
•
MINERAL SALTS
-
Your ChloroMatic system can also be used with all available pool salts, including
mineral salts containing Magnesium and Potassium.
When used exclusively with mineral salt pools, the
chlorine production is 50% of the normal rated output. However, if used as an additive to normal salt
pools, the rated output is similar.
Connect manual vacuum system and turn on filtration pump, slowly vacuum until salt dispersal is complete.
Place vacuum head into deepest end of pool and allow vacuum to continue for a further 2 to 3 hours. Salt
should now be completely mixed. For pop up automatic “In-Floor” cleaning systems allow the filter pump to
run for 2 to 3 hours. Never add salt directly into skimmer box.
•
CHLORINE
- For a new pool installation that has not been chlorinated, add sufficient Chlorine (liquid or
granular) to achieve a reading of 3 ppm (with a suitable test kit), or run the chlorinator system continuously
for at least 24 hours or until a reading of 3 ppm is reached.
Do not use a double adaptor to connect more than one pump - it can overload the system and could
void your warranty.
ESR Series
Black sleeved
terminal on lead to
Black terminal on cell.
White sleeved
terminal on lead to
White terminal on cell.
Red sleeved terminal
on lead to threaded
bolt on cell
ESC/ESCpH Series
Either Black sleeved terminal
on lead to either terminal on
cell.
Blue sleeved terminal on lead
to threaded bolt on cell.
LEADS
LEADS
ESR CELL
ESR CELL
ESC 16-40 CELL
LEADS
Gas sensor:
RED
BLACK
WHITE
Gas sensor:
RED
BLACK
WHITE
Gas sensor:
BLUE
BLACK
WHITE
THREADED
BOLT
BLACK
WHITE
THREADED
BOLT
BLACK
BLACK
THREADED
BOLT
THREADED
BOLT
ESC 50 CELL
ESC 50
CONNECTION
PINS - BLACK
PRE JUNE 2015
POST JUNE 2015