background image

18

Davey Repair or Replacement Guarantee

In the unlikely event in Australia or New Zealand that this Davey product develops any malfunction within 
warranty periods beginning from the date of original purchase due to faulty materials or manufacture, Davey 
will at our option repair or replace it for you free of charge, subject to the conditions below.

Should you experience any difficulties with your Davey product, we suggest in the first instance that you 
contact the Davey Dealer from which you purchased the Davey product. Alternatively you can phone our 
Customer Service line on 1300 232 839 in Australia, or 0800 654 333 in New Zealand, or send a written 
letter to Davey at the address listed below. On receipt of your claim, Davey will seek to resolve your 
difficulties or, if the product is faulty or defective, advise you on how to have your Davey product repaired, 
obtain a replacement or a refund.
Your Davey Guarantee naturally does not cover normal wear or tear, replacement of product consumables 
(i.e. mechanical seals, bearings or capacitors), loss or damage resulting from misuse or negligent handling, 
improper use for which the product was not designed or advertised, failure to properly follow the provided 
installation and operating instructions, failure to carry out maintenance, corrosive or abrasive water or other 
liquid, lightning or high voltage spikes, or unauthorized persons attempting repairs.  Where applicable, your 
Davey product must only be connected to the voltage shown on the nameplate.
Your Davey Guarantee does not cover freight or any other costs incurred in making a claim. Please retain 
your receipt as proof of purchase; you 

MUST

 provide evidence of the date of original purchase when 

claiming under the Davey Guarantee. 
Davey shall not be liable for any loss of profits or any consequential, indirect or special loss, damage or 
injury of any kind whatsoever arising directly or indirectly from Davey products. This limitation does not 
apply to any liability of Davey for failure to comply with a consumer guarantee applicable to your Davey 
product under the Australian or New Zealand legislation and does not affect any rights or remedies that 
may be available to you under the Australian or New Zealand Consumer Legislation.
In Australia, you are entitled to a replacement or refund for a major failure and for compensation for any 
other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced 
if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
Should your Davey product require repair or service after the guarantee period; contact your nearest Davey 
Dealer or phone the Davey Support Centre on the number listed below.
For a complete list of Davey Dealers visit our website (davey.com.au) or call:

*  Installation and operating instructions are included with the product when purchased new. 

They may also be found on our website.

Davey Guarantee Period

Power Supply - Three Years                         pH Pump Module - One Year

 

 

Electrolytic Cell - Three Years                      Sensor Probe - One Year 

AUSTRALIA
Head Offi ce

6 Lakeview Drive,

Scoresby, Australia 3179

Ph: 

1300 232 839

Fax: 

1300 369 119

Email: [email protected]

Website: davey.com.au

Davey Water Products Pty Ltd
Member of the GUD Group
ABN 18 066 327 517

NEW ZEALAND

7 Rockridge Avenue,

Penrose, Auckland 1061

Ph: 

0800 654 333

Fax: 

0800 654 334

Email: [email protected]

Website: daveynz.co.nz

EUROPE

ZAC des Gaulnes

355 Avenue Henri Schneider

69330 Meyzieu, France

Ph: 

+33 (0) 4 72 13 95 07

Fax: 

+33 (0) 4 72 33 64 57

Email: [email protected]

Website: daveyeurope.eu

INTERNATIONAL
Australian Head Offi ce

Ph: 

+613 9730 9124

Fax: 

+613 9753 4248

Email: [email protected]

Website: davey.com.au

® Davey is a trademark of Davey Water Products Pty Ltd.  © Davey Water Products Pty Ltd 2017.

NORTH AMERICA

Ph: 

+1 866 328 7867

Email: [email protected]

Website: daveyusa.com

MIDDLE EAST

Ph: 

+971 50 6368764

Fax: 

+971 6 5730472

Email: [email protected]

Website: daveyuae.com

Содержание ChloroMatic MCS16C

Страница 1: ...C MCS40C MC16CT 12 Volt Light Output included MCS50C MC20CT 12 Volt Light Output included MCS16CT 12 Volt Light Output included MCS24CT 12 Volt Light Output included Installation Operating Instruction...

Страница 2: ...ion Operating Instructions Packing List 2 Important Notice 3 Installation Instructions 4 Pre Start Up Procedure 5 Operation of your ChloroMatic System 6 ESR ESC Series with optional pH System Features...

Страница 3: ...lectrolytic cell is recommended The Cell is the unit containing the plates During the chlorination process a white powdery Calcium scale may naturally build up on the titanium plates in the cell Monit...

Страница 4: ...g Power Supply to a brick or concrete wall When mounting on a wall or a post in the pool equipment area drill pilot holes and fit screws provided Once screws are in position simply hang chlorinator vi...

Страница 5: ...te Place vacuum head into deepest end of pool and allow vacuum to continue for a further 2 to 3 hours Salt should now be completely mixed For pop up automatic In Floor cleaning systems allow the filte...

Страница 6: ...cell 3 Water temperature very cold Switch to Winter Mode Continued operation may cause damage to system Consult dealer for problem rectification PLEASE NOTE When Winter Mode switch is On Unit will ope...

Страница 7: ...operation simply turn the Sanitiser Output Control to MAX and the Cell will turn ON Once checked adjust the Sanitiser Output Control back to the desired position and after a few minutes the Cell will...

Страница 8: ...designed to operate at swimming season water temperatures When the pool begins to cool in the off season the temperature drop causes the Cell to behave differently it will draw less electrical curren...

Страница 9: ...ime sequence Select the Set Timer 2 ON position on the selector switch A number 4 will appear at the left of the screen This time is factory pre set to 5pm Proceed as per a in the Set Clock instructio...

Страница 10: ...required please refer to your ChloroMatic Davey dealer or the Davey Customer Service Centre BLACK RED TERMINAL SOCKET IN THE BASE OF THE UNIT This terminal socket may accept light connection in two w...

Страница 11: ...l output reverse polarity Model ESC40 cells will require earlier replacement than ESC24 Models operating under equivalent conditions Model ESC40 systems use the same cell as the ESC24 The correct Chlo...

Страница 12: ...p the pH constant may cause staining etching and corrosion of metals High Total Alkalinity will cause constantly high pH levels 3 SALT LEVELS Salt is the essential element by which your Unit operates...

Страница 13: ...e in your pool in order to maintain absolute sanitation of the water This can be achieved by adding either liquid or granulated chlorine If granulated chlorine is added the Cell must be checked regula...

Страница 14: ...ll ppm An abbreviation for Parts Per Million the accepted measurement of chemical concentration in swimming pool water I ppm l mg L The appropriate chlorinator size for your pool is dependent on the l...

Страница 15: ...hed off 2 Chlorinator not plugged into main outlet 3 Pump not plugged into Chlorinator 4 Time Clock set to Off position Power switch turned Off 5 Sanitiser Output Control turned to lowest setting 6 Ch...

Страница 16: ...e other end of the clear tube to the inlet port of the peristaltic pump The inlet port is the left side of the inverted U shaped tube on the pump indicated by an arrow pointing up on the clear plastic...

Страница 17: ...pH Dosing Pump Model M5135 Flow Flow IEC Male Plug from pH Dosing Pump Model M5138 M5138 Example of ESC50 NOTE NeverconnectyourpHpumpdirecttomainspower Alwaysconnectittothechlorinator power supply eit...

Страница 18: ...ever arising directly or indirectly from Davey products This limitation does not apply to any liability of Davey for failure to comply with a consumer guarantee applicable to your Davey product under...

Страница 19: ...19...

Страница 20: ...Ph 33 0 4 72 13 95 07 Fax 33 0 4 72 33 64 57 Email info daveyeurope eu Website daveyeurope eu INTERNATIONAL Australian Head Of ce Ph 613 9730 9124 Fax 613 9753 4248 Email export davey com au Website...