INSTALLING THE pH PERISTALTIC PUMP MODULE:

Refer to the procedures described in the “Davey Peristaltic Pump AS Series”, Installation and Operating 

Instructions.

NOTE: INSTRUCTIONS FOR DILUTING POOL ACID

The ChloroMatic Salt Water Chlorinator with pH control, automatically doses a diluted acid solution into the pool 

when the pH level needs to be reduced. The peristaltic pump draws this diluted acid from a container in which the 

solution is mixed.
Use the table below to determine what water/acid ratio is recommended for your pool, in an approved 20 litre 

Hydrochloric Acid container. 

IMPORTANT: KEEP BARE HANDS AWAY FROM POOL ACID AND ALWAYS USE CAUTION WHEN 

HANDLING POOL CHEMICALS.

Pool Size

Recommended Water/Acid 

Dilution Ratio

Volumes for a Suitable 

20 Litre Container

Water (parts)

Acid (parts)

Water (Litres)

Hydrochloric 

Acid (litres)

Up To 100,000 litres

5

1

17

3

Above 100,000 litres to 160,000 litres

3

1

15

5

Note: These ratios are based on Hydrochloric Acid strength of 28% and should not be any greater than this percentage.
Please ensure that you use a suitable container with resistance to Hydrochloric Acid. 

These containers can be purchased at pool stores.

   IMPORTANT: KEEP BARE HANDS AWAY FROM POOL ACID AND ALWAYS USE CAUTION WHEN 

HANDLING POOL CHEMICALS.

Installing the Acid Dosing Fittings & Attachments 

•  Locate the pool acid container a minimum horizontal distance of approximately 1m distance to the dosing 

pump and the Chloromatic controller, to avoid possible corrosive damage from chemical vapour 

•  Cut a length of the clear tube (supplied), to be able to be fed into the base of the acid container
•  Remove the cap from the acid container and rinse it in fresh water
•  Drill a 9mm hole through the centre of cap. Feed one side of the clear tube through the top of the cap, and 

secure it to the foot filter 

•  Push enough tube through the cap to allow the foot filter to sit at the bottom of the acid container. 

Secure the other end of the clear tube to the inlet port of the peristaltic pump. (The inlet port is the left side 

of the inverted “U” shaped tube on the pump indicated by an arrow pointing up on the clear plastic cover)

•  Re - fit the assembled cap to the acid container at the end when all tubes and fittings are connected 

through the system to avoid any syphoning of the acid from the container

•  Fit all the saddle clamps to the pipe work as shown in the “Davey Peristaltic Pump AS Series”, Installation 

and Operating Instructions and then attach the remaining clear tube (trim to length if required) to the 

discharge port of the peristaltic pump (on right side of inverted “U” shaped tube on the pump, indicated by 

arrow pointing down on clear plastic cover)

IMPORTANT: ENSURE SENSOR PROBE ALWAYS REMAINS MOIST. A NON-RETURN VALVE MAY 

NEED TO BE FITTED IN THE POOL FILTRATION LINE TO STOP DRAINAGE IN THE  PLUMBING. THE 

SENSOR PROBE MAY BE DAMAGED BEYOND REPAIR IF LEFT TO DRY OUT. WARRANTY WILL BE 

VOID IF THIS TYPE OF DAMAGE IS APPARENT.

For optimal service life of your peristaltic pump tube, it is advised not to exceed a pressure of 1 bar and 

under no circumstances exceed a pressure of 1.5 bar.
In the case of an installation with redox and pH regulation, it is advised to put the two sensors side by side 

and pH injection before chlorine injection to minimise the risk of scale deposition on the chlorine injection.

MAINTENANCE OF SENSORS, PUMP MODULE AND ROLLER HOLDER

The Peristaltic Pump uses a roller holder and a “squeeze” tube to pump the acid into the pool. This tube is 

perishable and must be replaced periodically. We recommend replacement approximately once per year. The 

tube should be visually inspected regularly for leaks or damage. It is recommended that the roller holder be 

periodically inspected and replaced every 2 years.

 

Refer to the Davey Peristaltic Pump AS Series Installation and Operating Instructions for details.
For further information on the operation and maintenance of the Davey Peristaltic pH Pump, please refer to the 

Peristaltic Pump Installation & Operating Instructions included with your ChloroMatic sanitiser.

Содержание ChloroMatic MCS16C

Страница 1: ...C MCS40C MC16CT 12 Volt Light Output included MCS50C MC20CT 12 Volt Light Output included MCS16CT 12 Volt Light Output included MCS24CT 12 Volt Light Output included Installation Operating Instruction...

Страница 2: ...ion Operating Instructions Packing List 2 Important Notice 3 Installation Instructions 4 Pre Start Up Procedure 5 Operation of your ChloroMatic System 6 ESR ESC Series with optional pH System Features...

Страница 3: ...lectrolytic cell is recommended The Cell is the unit containing the plates During the chlorination process a white powdery Calcium scale may naturally build up on the titanium plates in the cell Monit...

Страница 4: ...g Power Supply to a brick or concrete wall When mounting on a wall or a post in the pool equipment area drill pilot holes and fit screws provided Once screws are in position simply hang chlorinator vi...

Страница 5: ...te Place vacuum head into deepest end of pool and allow vacuum to continue for a further 2 to 3 hours Salt should now be completely mixed For pop up automatic In Floor cleaning systems allow the filte...

Страница 6: ...cell 3 Water temperature very cold Switch to Winter Mode Continued operation may cause damage to system Consult dealer for problem rectification PLEASE NOTE When Winter Mode switch is On Unit will ope...

Страница 7: ...operation simply turn the Sanitiser Output Control to MAX and the Cell will turn ON Once checked adjust the Sanitiser Output Control back to the desired position and after a few minutes the Cell will...

Страница 8: ...designed to operate at swimming season water temperatures When the pool begins to cool in the off season the temperature drop causes the Cell to behave differently it will draw less electrical curren...

Страница 9: ...ime sequence Select the Set Timer 2 ON position on the selector switch A number 4 will appear at the left of the screen This time is factory pre set to 5pm Proceed as per a in the Set Clock instructio...

Страница 10: ...required please refer to your ChloroMatic Davey dealer or the Davey Customer Service Centre BLACK RED TERMINAL SOCKET IN THE BASE OF THE UNIT This terminal socket may accept light connection in two w...

Страница 11: ...l output reverse polarity Model ESC40 cells will require earlier replacement than ESC24 Models operating under equivalent conditions Model ESC40 systems use the same cell as the ESC24 The correct Chlo...

Страница 12: ...p the pH constant may cause staining etching and corrosion of metals High Total Alkalinity will cause constantly high pH levels 3 SALT LEVELS Salt is the essential element by which your Unit operates...

Страница 13: ...e in your pool in order to maintain absolute sanitation of the water This can be achieved by adding either liquid or granulated chlorine If granulated chlorine is added the Cell must be checked regula...

Страница 14: ...ll ppm An abbreviation for Parts Per Million the accepted measurement of chemical concentration in swimming pool water I ppm l mg L The appropriate chlorinator size for your pool is dependent on the l...

Страница 15: ...hed off 2 Chlorinator not plugged into main outlet 3 Pump not plugged into Chlorinator 4 Time Clock set to Off position Power switch turned Off 5 Sanitiser Output Control turned to lowest setting 6 Ch...

Страница 16: ...e other end of the clear tube to the inlet port of the peristaltic pump The inlet port is the left side of the inverted U shaped tube on the pump indicated by an arrow pointing up on the clear plastic...

Страница 17: ...pH Dosing Pump Model M5135 Flow Flow IEC Male Plug from pH Dosing Pump Model M5138 M5138 Example of ESC50 NOTE NeverconnectyourpHpumpdirecttomainspower Alwaysconnectittothechlorinator power supply eit...

Страница 18: ...ever arising directly or indirectly from Davey products This limitation does not apply to any liability of Davey for failure to comply with a consumer guarantee applicable to your Davey product under...

Страница 19: ...19...

Страница 20: ...Ph 33 0 4 72 13 95 07 Fax 33 0 4 72 33 64 57 Email info daveyeurope eu Website daveyeurope eu INTERNATIONAL Australian Head Of ce Ph 613 9730 9124 Fax 613 9753 4248 Email export davey com au Website...

Отзывы: