background image

3

IMPORTANT NOTICE

FACTORS THAT WILL IMPROVE THE PERFORMANCE 

AND LIFE OF YOUR SALT WATER CHLORINATOR

PLEASE READ THIS BEFORE OPERATING YOUR CHLORINATOR

POOL BUILDERS:

  Please cover this information with your customer during the 

new pool “Hand over Session”

Salt Water Chlorinators are a valuable piece of pool sanitising equipment and must be cared for to 

get the best performance and life span from it.

There are 

THREE

 main factors that will damage your chlorinator and reduce the life of the product. 

Please monitor the following factors in accordance with your installation & operating instructions.

1. MAINTAIN OPTIMUM SALT LEVELS:

 

OPTIMUM SALT LEVELS: 4500-6000ppm

• Run chlorinator at the Optimum Salt Levels stated within this document and on the product to 

ensure optimum sanitiser output and cell life.

• Operating this device at low salt levels will damage the cell and reduce its life.

• The control panel displays red LED indicator warnings when the salt levels are low.

• If no action is taken to rectify the salt levels, damage to the cell may result which will not be 

covered under warranty.

2. MONITOR & MAINTAIN YOUR CHLORINATOR CELL:

• To keep your salt water chlorinator in the best possible condition, regular monitoring of the 

electrolytic cell is recommended. The ‘Cell’ is the unit containing the plates.

• During the chlorination process a white powdery Calcium scale may naturally build up on the 

titanium plates in the cell.  Monitor the cell to prevent excessive scale build up. Excessive scale 

build up will cause damage to your cell, and dramatically reduce its efficiency and lifespan.

• Reverse Polarity models are low maintenance models that minimise scale build up.

• The control panel displays red LED indicator warnings when the cell requires cleaning.

• If calcium scale builds up please clean the cell, following the cleaning instructions 

provided on page 11.

• 

NEVER:

 Use concentrated acid to clean your cell.

• 

NEVER:

 Leave cell in cleaning solution for extended periods of time

• 

NEVER:

 Use metal implements, scourers or brushes to clean your cell

3. BALANCED POOL WATER CHEMISTRY:

• Salt levels MUST be maintained at 4500-6000ppm for optimum performance and lifespan

• Calcium Hardness levels 

MUST

 be kept to ideal ranges of 

200-275ppm

 (for Concrete and 

Tiled Pools) and 

100-225ppm

 (for other surfaces) to prevent excessive scale build up and 

damage to equipment.

• pH levels 

MUST

 be kept to ideal levels to prevent damage to equipment and pool surfaces 

and to obtain optimum sanitiser effectiveness.

• Total Alkalinity and Stabiliser levels must also be kept in an ideal range. 

Note: Please refer to the RECOMMENDED POOL WATER CHEMISTRY chart on page 14 for 

more information.

Salt Water Pool System

Содержание ChloroMatic MCS16C

Страница 1: ...C MCS40C MC16CT 12 Volt Light Output included MCS50C MC20CT 12 Volt Light Output included MCS16CT 12 Volt Light Output included MCS24CT 12 Volt Light Output included Installation Operating Instruction...

Страница 2: ...ion Operating Instructions Packing List 2 Important Notice 3 Installation Instructions 4 Pre Start Up Procedure 5 Operation of your ChloroMatic System 6 ESR ESC Series with optional pH System Features...

Страница 3: ...lectrolytic cell is recommended The Cell is the unit containing the plates During the chlorination process a white powdery Calcium scale may naturally build up on the titanium plates in the cell Monit...

Страница 4: ...g Power Supply to a brick or concrete wall When mounting on a wall or a post in the pool equipment area drill pilot holes and fit screws provided Once screws are in position simply hang chlorinator vi...

Страница 5: ...te Place vacuum head into deepest end of pool and allow vacuum to continue for a further 2 to 3 hours Salt should now be completely mixed For pop up automatic In Floor cleaning systems allow the filte...

Страница 6: ...cell 3 Water temperature very cold Switch to Winter Mode Continued operation may cause damage to system Consult dealer for problem rectification PLEASE NOTE When Winter Mode switch is On Unit will ope...

Страница 7: ...operation simply turn the Sanitiser Output Control to MAX and the Cell will turn ON Once checked adjust the Sanitiser Output Control back to the desired position and after a few minutes the Cell will...

Страница 8: ...designed to operate at swimming season water temperatures When the pool begins to cool in the off season the temperature drop causes the Cell to behave differently it will draw less electrical curren...

Страница 9: ...ime sequence Select the Set Timer 2 ON position on the selector switch A number 4 will appear at the left of the screen This time is factory pre set to 5pm Proceed as per a in the Set Clock instructio...

Страница 10: ...required please refer to your ChloroMatic Davey dealer or the Davey Customer Service Centre BLACK RED TERMINAL SOCKET IN THE BASE OF THE UNIT This terminal socket may accept light connection in two w...

Страница 11: ...l output reverse polarity Model ESC40 cells will require earlier replacement than ESC24 Models operating under equivalent conditions Model ESC40 systems use the same cell as the ESC24 The correct Chlo...

Страница 12: ...p the pH constant may cause staining etching and corrosion of metals High Total Alkalinity will cause constantly high pH levels 3 SALT LEVELS Salt is the essential element by which your Unit operates...

Страница 13: ...e in your pool in order to maintain absolute sanitation of the water This can be achieved by adding either liquid or granulated chlorine If granulated chlorine is added the Cell must be checked regula...

Страница 14: ...ll ppm An abbreviation for Parts Per Million the accepted measurement of chemical concentration in swimming pool water I ppm l mg L The appropriate chlorinator size for your pool is dependent on the l...

Страница 15: ...hed off 2 Chlorinator not plugged into main outlet 3 Pump not plugged into Chlorinator 4 Time Clock set to Off position Power switch turned Off 5 Sanitiser Output Control turned to lowest setting 6 Ch...

Страница 16: ...e other end of the clear tube to the inlet port of the peristaltic pump The inlet port is the left side of the inverted U shaped tube on the pump indicated by an arrow pointing up on the clear plastic...

Страница 17: ...pH Dosing Pump Model M5135 Flow Flow IEC Male Plug from pH Dosing Pump Model M5138 M5138 Example of ESC50 NOTE NeverconnectyourpHpumpdirecttomainspower Alwaysconnectittothechlorinator power supply eit...

Страница 18: ...ever arising directly or indirectly from Davey products This limitation does not apply to any liability of Davey for failure to comply with a consumer guarantee applicable to your Davey product under...

Страница 19: ...19...

Страница 20: ...Ph 33 0 4 72 13 95 07 Fax 33 0 4 72 33 64 57 Email info daveyeurope eu Website daveyeurope eu INTERNATIONAL Australian Head Of ce Ph 613 9730 9124 Fax 613 9753 4248 Email export davey com au Website...

Отзывы: