DAT 6000
10
PRELIMINARY
DAT 6013 - DAT 6023
Voltage
Input
Min
Max
10 V
-10 V
+10 V
Current
Input
Min
Max
20 mA
-20 mA
+20 mA
Channels:
2 ( DAT 6013 )
4 ( DAT 6023 )
Input Type:
± 10V or ± 20 mA *
Calibration Accuracy:
± 0.05 %
Linearity:
± 0.1 %
Input Impedance:
> 1MOhm for V ; 47 Ohm for mA
Thermal Drift:
± 0.005 % F.S. /°C
Sampling Rate:
10 samples./sec
Bandwidth:
4 Hz
* For DAT 6023 the input type is not configurable.
It must be to defined at order (V or mA).
Supply Voltage:
24 Vdc typical (30 Vdc max)
ON state voltage:
> 9 Vdc
Input Impedance
(ENABLE, CLK):
4.7 KOhm
Minimum Output Load
(DATA):
560 Ohm
Maximum Clock signal frequency:
< 500 Hz (with 1ms filter)
< 50 Hz (with 10ms filter)
Debounce Filter:
settable to 1ms or 10 ms
Rise Time:
<0.2 ms
DIGITAL INTERFACE
Содержание DAT 6000 SERIES
Страница 6: ...DAT 6000 6 PRELIMINARY 3 wires RTD Res wiring 2 wires RTD Res wiring DAT 6012 Potentiometer wiring ...
Страница 7: ...DAT 6000 7 PRELIMINARY mA wiring V wiring DAT 6023 V wiring DAT 6013 mA wiring ...
Страница 19: ...DAT 6000 19 PRELIMINARY NOTE ...
Страница 20: ...DAT6012 2 Channel RTD PLC Input Phone 1 561 779 5660 E mail Info datexel com Web Site www datexel com ...