DAT 6000
9
PRELIMINARY
DAT 6012
RTD
Input
Min
Max
Pt100
-200°C
+850°C
Pt1000
-200°C
+200°C
Ni100
-80°C
+180°C
Ni1000
-60°C
+150°C
Resistance
Input
Min
Max
Low
0 Ohm
500 Ohm
High
0 Ohm
2000 Ohm
Potentiometer
Input
Min
Max
<500 Ohm
0 %
100 %
<2000 Ohm
0 %
100 %
Channels:
2
Input Type:
RTD (Pt100, Pt1000, Ni100, Ni1000)
Resistance and Potentiometer (up to 2KOhm)
Calibration Accuracy:
± 0.1°C for RTD; ± 0.1 Ohm for Resistance;
± 0.1 % for Potentiometer;
RTD Linearity:
± 0.2 °C
RTD Excitation Current:
0.350 mA typ.
Lead wire resistance influence:
< 0.05 %/Ohm (50 Ohm max.) for 3 wires RTD
Thermal Drift:
± 0.005 % F.S. /°C for RTD
Sampling Rate:
10 samples/sec
Bandwidth:
4 Hz
Содержание DAT 6000 SERIES
Страница 6: ...DAT 6000 6 PRELIMINARY 3 wires RTD Res wiring 2 wires RTD Res wiring DAT 6012 Potentiometer wiring ...
Страница 7: ...DAT 6000 7 PRELIMINARY mA wiring V wiring DAT 6023 V wiring DAT 6013 mA wiring ...
Страница 19: ...DAT 6000 19 PRELIMINARY NOTE ...
Страница 20: ...DAT6012 2 Channel RTD PLC Input Phone 1 561 779 5660 E mail Info datexel com Web Site www datexel com ...