Faderstart/ buttonstart
The BCS26(E) module is able to remote start connected equipment by faderstart, buttonstart or a
combination of these two options. By changing jumpers you easily select one of these settings.
The jumpers for remote start settings can be found at the main PCB above the bussconnector
(jumper J8 and J9, see drawing).
Jumpers J8 and J9 select the type of operation. It is possible to choose between faderstart (figure
6), buttonstart (figure 7) or the fader-switch combinaton (figure 8).
On-air channels
The BCS25 has two on-air groups. This makes it possible to drive an indicator when the
microphones are opened. The output will be activated when one or more channels that belong to
the on-air group are opened.
With jumper J12 a channel is configured as on-air 1 or on-air 2 channel. When a channel is
configured as on-air 1 the studio output will be muted when the channel is active. The on-air 1
output on the master also will be activated. A channel configured as on-air 2 will not mute the
studio, but only activate the on-air 2 output on the master.
Fig. 7
Fig. 8
Fig. 6