Firmware ver 1.41.32 

 

  

 

Outlet Commands 

Description 

get outlets 

Returns the name and status of outlets with user rights 

get outlet <n> 

Returns the name and status of outlet n (with user rights) 

set outlet <n> <on/off/cycle> 

Commands  outlet  n  to  power  on/off  or  cycle  (reboot  or 
power pulse) 

set outlets <nnnnnnnn> 

Controls outlets to on or off using binary place value. 
(n = 0 for off and n = 1 for on) 

see Multi Outlet Control

 

set outlet <n> name <name> 

Each  outlet  can  be  named  for  easy  identification.  20 
characters, no spaces. 

get outlet <n> initial.state 

Set/Get the initial state of each outlet when the iBootBar is 
first powered up. 

see Frequent Outlet Control

 

set outlet <n> initial.state <last/on/off> 

Set/Get the initial state of each outlet when the iBootBar is 
first powered up. 
Returns the current AutoPing configuration for outlet <n> 

get outlet <n> autoping 

set outlet <n> autoping ipaddress <dotted decimal> 

Set the IP address to be pinged for AutoPing 

set outlet <n> autoping action <action> 

Set the action to be performed when AutoPing is triggered.  
none / on-latch / on-follow / off-latch / off-follow / cycle / 
cycle-once 

set outlet <n> autoping frequency <0-999> 

Set the delay between ping attempts 

set outlet <n> autoping count <0-99> 

Set  the  number  of  failures  to  respond  to  ping  before  the 
AutoPing feature is triggered 

 

Network Commands 

Description 

get network 

Display current ipmode, ipaddress, subnet, gateway  
parameters 

set ipmode <arp-ping/static/dhcp> 

Set the mode of setting the IP address of the iBootBar. 

set ipaddress <dotted decimal> 

Set the current IP address.  ipmode must be set to static to 
use this command. 

set subnet <dotted decimal> 

Set the Subnet Mask  

set gateway <dotted decimal> 

Set the Gateway.   

get telnet 

Display current telnet enable, telnet port parameters 

set telnet enable <yes/no> 

Enable or Disable Telnet Server 

set telnet port <1-65535> 

Change the Telnet Server IP port. (default 23) 

get protocol 

Display the current direct messaging protocol 

set protocol enable <ipal/rps/none> 

Select direct messaging protocol, or none 

set protocol port <1-65535> 

set the port for the messaging  protocol (default 9100) 

get upload enable 

Enable or Disable firmware uploading capability. 

set upload enable <yes/no> 

get time 

Returns the current time 

set time server <dotted decimal> 

Set the time manually or use a time server.  If a timeserver 
is used, provide the time zone offset. 

set time usents <yes\no> 

get telnet 

Display current telnet enable, telnet port parameters 

set telnet enable <yes/no> 

Enable or Disable Telnet Server 

set telnet port <1-65535> 

Change the Telnet Server IP port. 

get snmp 

Display current SNMP parameters 

set snmp writecommunity <name>  

32 characters max 

set snmp readcommunity <name>  

32 characters max 

set snmp <n> ipaddress <dotted decimal> 

Set up to <n>=1-4 SNMP manager addresses 

set snmp <n> enable <yes/no> 

Enable or Disable SNMP for manager <n> 

get email 

Setup email delivery of status and alarm changes.  Set the 
server  address,  return  address,  username  and  password 
needed to authorize email delivery. 

set email server <dotted decimal> 

set email address <return address> 

set email username <user name 128 char max> 

 

 - Reboot is required for these settings to take effect. (

reboot 

command, reset button or power cycle unit.) 

Содержание iBootBar iBP-2C10

Страница 1: ...MA 20 Amp 8 x NEMA 5 15 IP Control Serial Control Internal Modem iBP 2N20 2 x NEMA 40 Amp 8 x NEMA 5 15 IP Control Serial Control iBP 2N20 M 2 x NEMA 40 Amp 8 x NEMA 5 15 IP Control Serial Control Int...

Страница 2: ...4 Installation 5 Configuration 7 Basic Operation 9 Command Line Interface Direct Messaging Protocols Advanced Operations 14 Frequent Outlet Control Multi Outlet Control DTMF Control AutoPing Email Not...

Страница 3: ...efeat the safety purpose of the grounding type plug Do not use a 3 to 2 prong adapter at the receptacle use of this type adapter may result in risk of electrical shock and or damage to this product 9...

Страница 4: ...ty The iBP has many features to make the management of power distribution simple and cost effective 8 Independently controllable outlets Dual power inputs for redundant power feeds Support for dual re...

Страница 5: ...the iBP to the standard 19 inch rack Ethernet The iBootBar has a 10 100 Ethernet port The default address is 192 168 0 254 Serial Port The iBootBar has a 9 pin D subminiature connector for RS 232 seri...

Страница 6: ...mum current load for all outlets cannot exceed 12 Amps at 115VAC or 10 Amps when used at 240VAC The iBP 2C10 M is for international applications and can be used on 100V to 240VAC The iBP 2C10 provides...

Страница 7: ...em 2 Automatically from a DHCP Server 3 ARP Ping To configure the mode to set the IP address access the iBootBar command line interface CLI and use the set ipmode command as indicated below Setting th...

Страница 8: ...ted decimal for the iBootBar and the MAC address is the MAC Address of the iBootBar The MAC Address of the iBootBar is located on the rear of the unit Example arp s 63 211 86 165 00 50 c2 05 01 c1 ent...

Страница 9: ...ycle The cycle time is the length of the reboot or power on In seconds 0 99 set cycle n get console Display current console configuration set console timeout 30 3600 disable Console can be set to auto...

Страница 10: ...address of the iBootBar set ipaddress dotted decimal Set the current IP address ipmode must be set to static to use this command set subnet dotted decimal Set the Subnet Mask set gateway dotted decima...

Страница 11: ...e Byte status for each outlets all 8 Bytes of status for each command Verbose Status for controlled outlet only Basic Syntax esc pass esc outlet cmd esc pass outlet cmd CR iPAL Protocol esc pass esc o...

Страница 12: ...Outlet ON C Cycle Outlet Cycle can be On Off On or Off On Off depending on starting status T Set Cycle Time Cycle time in seconds Valid range 1 99 Get Status Outlet number optional No outlet number w...

Страница 13: ...er on or off to improve product life expectancy for example set outlet 1 initial state on set outlet 4 initial state off Multi Outlet Control Command This command is used to operate all eight outlets...

Страница 14: ...e key is used to reboot or power cycle the outlet for the time configured with the CLI command cycle time The new status of the outlet is stated If the key is used the iBootBar will also state begin t...

Страница 15: ...low Upon triggering iBootBar will power off the assigned outlet When the ping response returns iBootBar will power the outlet on Cycle Upon triggering iBootBar will cycle the power to the assigned out...

Страница 16: ...abled using the set upload enable yes command on the console interface To upgrade the iBootBar download the latest version of the firmware and upgrade utility from the Dataprobe website http Dataprobe...

Страница 17: ...M C14 8 x C13 I S M iBP 2C10 2 x C14 8 x C13 I S iBP 2C10 M 2 x C14 8 x C13 I S M iBP C20 C20 8 x C13 I S iBP C20 M C20 8 x C13 I S M iBP 2C20 2 x C20 8 x C13 I S iBP 2C20 M 2 x C20 8 x C13 I S M Key...

Страница 18: ...n for help This device complies with Part 15 of the FCC rules Operation of this device is subject to the following conditions 1 This device may not cause harmful interference and 2 this device must ac...

Страница 19: ...current country setting Note Use of the wrong countrycode violates local laws and the warranty of this product Country countrycode Argentina 07 Australia 09 Austria 253 Belgium 253 Canada 181 China 1...

Страница 20: ...r32 delayTime 2 TB snmpManagerTable 1 TE snmpManagerEntry 1 RO Integer32 snmpManagerIndex 2 RW DisplayString snmpManagerIPAddress 3 RW INTEGER Enum snmpManagerEnable 3 TB outletTable 1 TE outletEntry...

Страница 21: ...Dataprobe Technical Service at 201 934 5111 to receive a Return Materials Authorization RMA Number prior to sending any equipment back for repair Include all cables power supplies and proof of purcha...