iboot-poe_v180808n
iBoot-PoE
Page 16
With AutoPing operational, the main iBoot-PoE page will display the current status of this feature. The
status will be OK to indicate that iBoot-PoE is receiving responses to the ping, or that the fail counter has
not yet been exceeded.
If the fail count has been exceeded, the status will change to FAIL. The Trigger Counter indicates the
number of times the AutoPing action has been triggered. A counter reset button is provided.
Note: All of the AutoPing Settings require a reboot of the iBoot-PoE, after clicking Save. A Reboot button
will appear at the bottom of the page. The new settings will not take effect until the unit is
rebooted. Reboot will not affect the power position of the iBoot-PoE. Upon Clicking Reboot, the
Goodbye page is displayed with a link to re-login.
Traffic Monitor
Traffic Monitor continuously samples the data throughput between the PD and the PSE and will provide
automatic reboot when the data rate drops below a set point. It can also set a Maximum rate for reboot,
plus time of day settings to temporarily disable the Traffic Monitor on a daily basis.
Traffic Monitor Enable: Enable or disable the Traffic Monitor Service.
Fail Time: Set the time, in seconds that the set rate must be measured before the reboot occurs.
Restart Time: Set the time in seconds after reboot that the Traffic Monitor will begin again to measure
traffic. Subsequent reboots will occur when the time equals the Restart Time plus the Fail Time.
Number of Cycles: Set the number of reboots to attempt for a single failure event.
Minimum Traffic: Sets the minimum data rate to trigger the Traffic Monitor. Can be set in Kbps or Mbps
Monitoring: Set whether the Traffic Monitor looks at the Uplink (PSE to PD), Downlink (PD to PSE) or
both. Each direction is independently monitored and the Minimum or Maximum setting is per direction.
Maximum Bandwidth: Test Enable: Enable or disable maximum bandwidth triggering
Maximum Bandwidth: Set the maximum data rate to trigger the Traffic Monitor. Can be set in Kbps or
Mbps.
Daily Monitor Disable: Set the start time and stop time for disabling the Traffic Monitor. Settings are in 24
hour format HH:MM.
5.6. Event Scheduling
iBoot-PoE can schedule up to eight
reoccurring power events. Set the
starting date and time, plus the action
to be taken and any repeat cycle for
each.
To enable the time scheduling
function set the network time server in
Advanced Network Setup, Section
5.3.
Once the time server is active,
scheduled events can occur. Up to eight independent scheduled events can be programmed.