Adjustments and Maintenance
2-12
Step
Action
Displayed Message
Comment(s)
15
Press the EXIT Key and, when
prompted, press the YES Key at
the SAVE CHANGES prompt.
OFFLINE
This completes the Advanced
Calibration procedure.
16
Press and hold the FEED Key
until at least one label has been
output.
CALIBRATION COMPLETE
followed by...
READY
The printer is now ready for
use.
Note: If calibration fails, try desensitizing the sensor: Re-enter the Advanced Menu. Go to Media
Settings / Sensor Calibration / Advanced Entry / (Tran or REFL) Sensor Gain then lower the
corresponding Gain Setting by one. Exit the menu and save your changes. Test your media at
the new setting. If necessary, repeat until a usable Gain setting is obtained.
2.2
Printhead Assembly Adjustments
To ensure consistent print quality across the full range of available media types and sizes, the printhead
assembly is equipped with an adjustable Leveling Cam and Printhead Burn Line.
Printhead Assembly