Adjustments and Maintenance
2-6
Step
Action
Displayed Message
Comment(s)
3
Press the ENTER Key to
access SENSOR
CALIBRATION. Use the UP
Button to scroll to
ADVANCED CALIBRATION
and press the ENTER Key.
ADVANCED CALIBRATION
You are beginning
ADVANCED ENTRY
calibration. Press the ESC
Key to abort this procedure.
4
Scroll to TRAN SENSOR GAIN
(or REFL SENSOR GAIN, if
using reflective media) then
press the ENTER Key.
TRAN SENSOR GAIN
(0 - 31)
YYY
25
The examples that follow
detail the calibration of die-cut
media; however, unless
otherwise noted, the
procedure for calibrating
reflective media is the same.
5
Install media. Position the
Media Sensor under the label,
then lower and latch the
Printhead Assembly.
TRAN SENSOR GAIN
(0 - 31)
YYY
25
If using preprinted media,
ensure the label area over the
sensor is free of text, graphics,
lines, etc.