Adjustments and Maintenance
2-9
Gain
Number
Label
Value
TOF
Value
Difference
Value
00
252
248
01
250
245
02
248
234
…
…
…
31
131
14
Step
Action
Displayed Message
Comment(s)
9
In the table, where both the
Label Value and TOF Value are
above 20, subtract them and
record the result as a Difference
Value (see below). Then find
the largest Difference Value in
your table – its corresponding
Gain Number will be used for
sampling the media.
TRAN SENSOR GAIN
(0 - 31)
YYY
08
In this example, Gain Number
08 is chosen because, where
both the Label Value (178) and
TOF Value (32) are above
twenty, it delivers the highest
Difference Value
(146).
Gain
Number
Label
Value
TOF
Value
Difference
Value
00
252
248
4
01
250
245
5
…
…
…
…
06
200
88
112
07
189
58
131
08
178
32
146
09
167
19
N/A
…
…
…
…
31
131
14
N/A
Step
Action
Displayed Message
Comment(s)
10
Use the UP and DOWN Buttons
to enter the Gain Number
determined in the previous step,
and then press the ENTER Key.
TRAN SENSOR GAIN
(0 - 31)
YYY
08
This example uses Gain
Number 08.