Chapter 3 – Printer Operation
33
Advanced Entry Calibration (continued)
Step
Action
Displayed Message
Comment
H
Raise the cover assembly then
proceed according to the media
type:
Die-cut – Remove a label or two
from the liner then position the
liner in the Media Sensor.
Notched – Position the Media in
the Media Sensor under the notch.
Reflective – Position the Media in
the Media Sensor under the black
mark.
TRAN SENSOR GAIN
09
31
(0 - 31)
(1) Do not position the Media
Sensor under a perforation; and
if using preprinted media, ensure
the label area placed over the
sensor is free of text, graphics,
lines, etc.
(2) Do not move the Media
Sensor after this step.
I
Lower and latch the Cover
Assembly.
Using the
or
button, set the
Gain Number to 0.
Record the reading as a TOF Value
for Gain Number 0 in the table.
TRAN SENSOR GAIN
248
0
(0 - 31)
This is the TOF Value for a gain
setting of 0, where “248”
represents the current sensor
reading.
Sample Calibration Table
Gain Number
Label Value
TOF Value
Difference Value
00 252 248
01 250
02 248
… …
31 09
Содержание E-Class Mark III Professional+
Страница 1: ...Operator s Manual Professional and Professional Models Professional Professional ...
Страница 2: ......
Страница 26: ...20 Chapter 2 Printer Setup ...
Страница 68: ...62 Chapter 5 Maintenance Adjustments ...
Страница 72: ...66 Chapter 6 Troubleshooting ...
Страница 76: ...70 Appendix A Specifications ...
Страница 84: ...78 Appendix B WLAN LAN Setup ...
Страница 86: ...80 Appendix C Bluetooth Setup ...
Страница 92: ......