Chapter 3 – Printer Operation
31
3.7.3
Advanced Entry Calibration
Advanced Entry is an alternate calibration method for special-case media types, where sensor readings are
taken using different sampling algorithms and from a list of these readings the best algorithm is selected for
manual entry into the database.
Advanced Entry Calibration should be used only when Manual Calibration proves unsuccessful.
Calibrate the Media Sensor using the steps below:
The Sensor Calibration menu item is only accessible in the Advanced Menu mode.
Step
Action
Displayed Message
Comment
A
Turn ON the printer.
Wait briefly for initialization to
complete.
B
Using the
button scroll to
MENU and press the
button.
Make sure MEDIA SETTINGS is
highlighted and press the
button.
Then using the
button, scroll to
SENSOR CALIBRATION.
(Printer Menu)
C
Press the
button to access
SENSOR CALIBRATION.
Make sure ADVANCED ENTRY is
highlighted and press the
button.
ADVANCED ENTRY
D
Scroll to TRAN SENSOR GAIN (or
REFL SENSOR GAIN, if using
reflective media) then press the
button.
TRAN SENSOR GAIN
202
17
(0 - 31)
The following examples detail die-cut
media calibration; however, unless
otherwise noted, the reflective media
procedure is the same.
E
Install media. Position the Media
in the Media Sensor and close the
cover.
TRAN SENSOR GAIN
202
17
(0 - 31)
Do not position the Media
Sensor under a perforation;
and if using preprinted media,
ensure the label area placed
over the sensor is free of text,
graphics, lines, etc.
Содержание E-Class Mark III Professional+
Страница 1: ...Operator s Manual Professional and Professional Models Professional Professional ...
Страница 2: ......
Страница 26: ...20 Chapter 2 Printer Setup ...
Страница 68: ...62 Chapter 5 Maintenance Adjustments ...
Страница 72: ...66 Chapter 6 Troubleshooting ...
Страница 76: ...70 Appendix A Specifications ...
Страница 84: ...78 Appendix B WLAN LAN Setup ...
Страница 86: ...80 Appendix C Bluetooth Setup ...
Страница 92: ......