Chapter 3 – Printer Operation
Advanced Entry Calibration (continued)
Step
Action
Displayed Message
Comment
N
Press the
button to exit the
current menu level.
Using the
button, scroll to
PAPER SENSOR LEVEL (or if using
reflective media, REFL PAPER
LEVEL) and then press the
button.
Using the
or
button, set the
Paper value determined in Step M
and then press the
button.
PAPER SENSOR LEVEL
174
(0 - 255)
This is the Paper value.
O
Using the
button, scroll to GAP
SENSOR LEVEL (or, if using
reflective media, MARK SENSOR
LEVEL) and then press the
button.
Using the
or
button, Set the
Gap (or Mark) value determined in
Step M and then press the
button.
GAP SENSOR LEVEL
042
(0 - 255)
This is the Gap (or Mark) value.
P
Using the
button, scroll to
EMPTY SENSOR LEVEL and then
press the
button.
Set the Empty value determined in
Step M and then press the
button.
EMPTY SENSOR LEVEL
9
(0 - 255)
This is the Empty value.
Q
Press the
repeatedly
to exit
the menu, select YES at the SAVE
CHANGES prompt and then press
the
button.
Save Changes?
No
>Yes
Save Changes. The printer is
ready for use.
If the calibration attempt fails, try desensitizing the sensor as follows:
Go to MEDIA SETTINGS / SENSOR CALIBRATION / ADVANCED ENTRY / TRAN (or REFL) SENSOR GAIN
and lower the corresponding GAIN SETTING by one.
Exit the menu and save your changes. Test your media at the new setting. If necessary, repeat until a
usable Gain Setting is obtained.
Содержание E-Class Mark III Professional+
Страница 1: ...Operator s Manual Professional and Professional Models Professional Professional ...
Страница 2: ......
Страница 26: ...20 Chapter 2 Printer Setup ...
Страница 68: ...62 Chapter 5 Maintenance Adjustments ...
Страница 72: ...66 Chapter 6 Troubleshooting ...
Страница 76: ...70 Appendix A Specifications ...
Страница 84: ...78 Appendix B WLAN LAN Setup ...
Страница 86: ...80 Appendix C Bluetooth Setup ...
Страница 92: ......