78
List of commonly used items:
group Addresses:
device start address (default 0)
device end address (default device size-1)
buffer start address (default 0)
Split
(default none)
This option allows setting special mode of buffer when programming or reading device. Using
split options is particularly useful when using 8-bit data memory devices in 16-bit or 32-bit
applications.
Following table describes buffer to device and device to buffer data transfer
Split type
Device
Buffer Address assignment
None
Device [ADDR]
Buffer [ADDR]
Even
Device [ADDR]
Buffer [2*ADDR]
Odd
Device [ADDR]
Buffer [1+(2*ADDR)]
1/4
Device [ADDR]
Buffer [4*ADDR]
2/4
Device [ADDR]
Buffer [1+(4*ADDR)]
3/4
Device [ADDR]
Buffer [2+(4*ADDR)]
4/4
Device [ADDR]
Buffer [3+(4*ADDR)]
Real addressing will be following: (all addresses are hexadecimal)
Split type
Device addresses
Buffer addresses
None
00 01 02 03 04 05
00 01 02 03 04 05
Even
00 01 02 03 04 05
00 02 04 06 08 0A
Odd
00 01 02 03 04 05
01 03 05 07 09 0B
1/4
00 01 02 03 04 05
00 04 08 0C 10 14
2/4
00 01 02 03 04 05
01 05 09 0D 11 15
3/4
00 01 02 03 04 05
02 06 0A 0E 12 16
4/4
00 01 02 03 04 05
03 07 0B 0F 13 17
Terms explanation:
Access to device address ADDR is written as Device [ADDR].
Access to buffer address ADDR is written as Buffer [ADDR].
ADDR value can be from zero to device size (in bytes).
All addresses are byte oriented addresses.
group Insertion test:
insertion test
(default ENABLE)
If enabled, the programmer checks all pins of the programmed chip, if have proper connection
to the ZIF socket (continuity test). The programmer is able to identify the wrong contact,
misinserted chip and also (partially) reversely inserted chip.
Device ID check error terminates the operation
(default ENABLE)
Programmer provides ID check before each selected action. It compares read ID codes from
device with ID codes defined by device manufacturer. In case of ID error, control program
behaves as follows:
if item is set to ENABLE, selected action is finished
if item is set to DISABLE, selected action continues. Control program just writes warning
message about ID error to LOG window.
If enabled, the programmer checks the electronic ID of the programmed chip.
Содержание 448PRO2AP
Страница 6: ...6 Introduction ...
Страница 11: ...DATAMAN 448PRO2AP AU 11 DATAMAN 448PRO2AP AU ...
Страница 19: ...DATAMAN 448PRO2AP 19 DATAMAN 448PRO2AP ...
Страница 26: ...26 DATAMAN 48PRO2AP ...
Страница 33: ...Setup 33 Setup ...
Страница 38: ...38 Step 8 Installation process will start Step 9 Click Finish button to finish setup ...
Страница 56: ...56 PG4UW ...
Страница 123: ...PG4UWMC 123 PG4UWMC ...
Страница 136: ...136 Installation procedure customized ...
Страница 145: ...Common notes 145 Common notes ...
Страница 157: ...Troubleshooting and warranty 157 Troubleshooting and warranty ...