Common notes
147
Biannual maintenance
Perform the Selftest for every programmer or programming module.
Annual maintenance
Gently clean the surface of the programmer with isopropyl alcohol or technical alcohol on a
soft cloth.
Perform the calibration test if the programmer supports this feature.
Warning:
The ZIF socket of the programming modules is considered as consumables. The life cycle of
the programming module ZIF socket is generally from 5.000 to 10.000 mechanical cycles,
even if the life cycle of some specialized BGA ZIF sockets can be about 500.000 mechanical
cycles. Programmed devices, environment and ZIF socket maintenance have direct influence
to actual electrical lifetime of ZIF socket (it means that ZIF socket does not cause
programming failures yet). Keep fingers away from contacts of ZIF socket, because contacts of
the ZIF socket fouled by smear and grime from fingers may cause the programming failures.
Change the ZIF socket or the socket converter if you noticed increased number of
programming failures.
The warranty does not apply to the ZIF sockets that are wear or grimy and which cause large
amount of failures during working with programmer.
Software
PG4UW is common control program for all of the DATAMAN programmers. Thus, during work
with him it is possible to find some items; those refer not to current selected programmer.
Command line parameters
We recommend using special utility pg4uwcmd.exe to make command line parameter control
of PG4UW. For backward compatibility there is possible to use some command line
parameters also directly with pg4uw.exe, but better way is to use pg4uwcmd.exe, which has
support of more command line commands and also it has capability to return ExitCode (or
ErrorLevel) value indicating success or error result of executing command line parameters. For
more information about using pg4uwcmd.exe command line controller for PG4UW, please
take a look at Remote command line control of PG4UW.
Command line parameters which can be used directly with pg4uw.exe
/Prj:<file_name>
forces project load when program is starting or even if program is
already running, <file_name> means full or relative project file path
and name
/Loadfile:<file_name> forces file load when program is starting or even if program is already
running, <file_name> means full or relative path to file that has to be
loaded, file format is detected automatically
/Saveproject:<file_name>
the command is used to save currently selected device type,
buffer contents and configuration to project file. Command
/Saveproject... is equivalent to user selected command Save
project in PG4UW control program.
Содержание 448PRO2AP
Страница 6: ...6 Introduction ...
Страница 11: ...DATAMAN 448PRO2AP AU 11 DATAMAN 448PRO2AP AU ...
Страница 19: ...DATAMAN 448PRO2AP 19 DATAMAN 448PRO2AP ...
Страница 26: ...26 DATAMAN 48PRO2AP ...
Страница 33: ...Setup 33 Setup ...
Страница 38: ...38 Step 8 Installation process will start Step 9 Click Finish button to finish setup ...
Страница 56: ...56 PG4UW ...
Страница 123: ...PG4UWMC 123 PG4UWMC ...
Страница 136: ...136 Installation procedure customized ...
Страница 145: ...Common notes 145 Common notes ...
Страница 157: ...Troubleshooting and warranty 157 Troubleshooting and warranty ...