DATAVS2-VSM INSTRUCTION MANUAL
18
7
7.3.2 ROI Change
To modify a ROI, the tool must have been selected previously and the
“Adjust Tools”
panel
opened.
The following operations are possible:
Move, Resize and Rotate.
NOTE
For the tools characterized by two ROIs, such as the Pattern Match or 360°
Pattern Match, the VSM allows editing only the ROI research.
NOTE
Press
TEACH
to confirm. When exiting the change mode, the user is
requested to discard changes or save them definitively in the flash memory.
All changes will be cancelled by selecting “Exit without saving”.
MOVE:
Once selected
“Move”
, the focus is transferred in the field range and the ROI can be moved
using the
ARROWS
.Once you have achieved the desired position, press
TEACH
to save
changes. Press
ESC
to return to the Setup menu ignoring the changes made.
RESIZE:
If you wish to modify the ROI size, select the
“Resize”
option from the Setup menu (using
the
SET
button again). It is now possible to increase or decrease the ROI size using the
ARROW
buttons.