POWER SUPPLY 

 

11 

 

Outputs 

+V 

Power Source - Outputs 

-V 

Power Reference - Outputs 

O1+ 

Output 1 + 

O1- 

Output 1 - 

O2+ 

Output 2 + 

O2- 

Output 2 - 

O3A 

 / Output 3 + (See Note) 

O3B 

Strobe - / Output 3 - 

RS232 Interface  

TX 

Transmit 

 

 

RX 

Receive 

 

 

SGND 

Signal Ground (See Caution) 

 

 

Note: The strobe signal connection is shared with Output 3. If a non-zero value is defined for the Strobe Pulse Length 

value (in VPM – Impact – General), the strobe is active. If the value is zero, Output 3 is active. 

 
 

 

NOTE 

To avoid electromagnetic interference when the camera is connected to a 

CBX connection box, verify the jumper positions in the CBX as indicated in 

its Installation Manual. 

POWER SUPPLY 

 

NOTE 

The T4x-Series does not support sourcing power towards the CBX through 

the CBX "power from device" source jumper setting. Power must be 

supplied to the CBX as shown below. 

 

To power the camera and/or I/O devices through the CBX, power must be supplied to the 

CBX500 spring clamp terminal pins as shown in Figure 4: 

 

 

Figure 4 - Power Supply Connections 

 

The power must be between 10 and 30 Vdc only. 

 

It is recommended to connect the device CHASSIS to earth ground (Earth) by setting the 

appropriate jumper in the CBX connection box. See the CBX Installation Manual for details. 

 

CAUTION 

Do not connect GND and SGND to different (external) ground references. 

GND and SGND are internally connected through filtering circuitry which 

can be permanently damaged if subjected to voltage drops over 0.8 Vdc. 

Содержание T4 Series

Страница 1: ...T4x Series QuickStart Guide Publication 821002560...

Страница 2: ...ger and Impact are trademarks of Datalogic Automation S r l All other brand and product names mentioned herein are for identification purposes only and may be trademarks or registered trademarks of th...

Страница 3: ...m and click on one of the following links for further information PRODUCTS Search through the links to arrive at your product page which describes specific Info Features Applications Models Accessorie...

Страница 4: ...may cause radio interference in which case the user may be required to take adequate measures FCC COMPLIANCE Modifications or changes to this equipment without the expressed written approval of DLA co...

Страница 5: ...E CAMERA The first step to perform is to assemble any accessories that make up the T4x Series camera A lens must be used A strobe or other external illuminator may be required CAUTION The camera must...

Страница 6: ...out shown in the figure below an EtherNet host is connected to the camera The camera can use an external trigger to signal image acquisition The CBX is used to facilitate the connection between the ca...

Страница 7: ...rnal trigger device photocell and additional I O connections Use the CAB GE0x for the Gigabit Ethernet connection to the host NOTE The T4x Series does not support sourcing power towards the CBX in ord...

Страница 8: ...ks during image and flash memory access 8 BUTTON Camera Reset See Note below To trigger the Camera Button event press and release the button Internal software event trigger only Note Camera Reset will...

Страница 9: ...es can be installed to operate in different positions using the body mounting bracket shown in Figure 3 Use the fourteen screw holes M4 on the body of the camera for custom mounting solutions The diag...

Страница 10: ...ions through one of the CBX connection boxes since they offer the advantages of easy connection easy device replacement and filtered reference signals The table below shows the terminal block connecti...

Страница 11: ...tion Manual POWER SUPPLY NOTE The T4x Series does not support sourcing power towards the CBX through the CBX power from device source jumper setting Power must be supplied to the CBX as shown below To...

Страница 12: ...aximum cable length must be less than 15 m 49 2 ft Figure 5 RS232 Main Interface Connections Using Hardware Handshaking INPUTS There are two optocoupled polarity insensitive inputs available on the ca...

Страница 13: ...g diagrams EXTERNAL TRIGGER INPUT CONNECTIONS USING CBX POWER CAUTION Power is available directly to the Input Device independently from the Power Supply Switch inside the CBX EXTERNAL TRIGGER Camera...

Страница 14: ...Signal V VCC I1A I1B Figure 9 NPN External Trigger Using External Power INPUT 2 CONNECTIONS INPUT 2 CONNECTIONS USING CBX POWER CAUTION Power is available directly to the Input Device independently f...

Страница 15: ...used either to signal the data collection result or to control an external lighting system The electrical features of the two outputs are the following VCE 30 Vdc max ICE 40 mA continuous max 130 mA p...

Страница 16: ...Using CBX Power Figure 15 Open Collector Output Using CBX Power OUTPUT CONNECTIONS USING EXTERNAL POWER Figure 16 Output Open Emitter Using External Power Figure 17 Output Open Collector Using Extern...

Страница 17: ...hed by the procedures described in the Impact Reference Guide VPM is used to configure the camera for specific applications and provides the tools to create vision programs VPM SYSTEM REQUIREMENTS To...

Страница 18: ...eted you can start VPM Changing the Camera s IP Address 1 Connect to the device with VPM 2 Select the Settings tab 3 Click the General System Object 4 Select the General radio button 5 Enter the desir...

Страница 19: ...the front of the processor DO NOT change any of the other Local Area Connections Changing any other connection can cause the M Series cameras to stop functioning 1 In the Start menu click on Control...

Страница 20: ...ART GUIDE 20 5 In the list of items select Internet Protocol Version 4 TCP IPv4 then click Properties 6 Select Use the following IP address 7 Enter the desired IP address 8 Click OK to close all the o...

Страница 21: ...ate T40 60 T47 15 T49 15 ENVIRONMENTAL FEATURES Operating Temperature 1 0 to 45 C 32 to 113 F Storage Temperature 20 to 70 C 4 to 158 F Max Humidity 90 non condensing Vibration Resistance 1 5 mm 5 to...

Страница 22: ...www datalogic com...

Отзывы: