MOUNTING THE CAMERA 

Using the T4x-Series mounting brackets, you can obtain rotation on the various axes of the 

camera as shown in the diagrams below. 

 

 

 

 

 

Figure 3 –Positioning with Body Mounting Bracket (Back) 

 

 

 

 

CBX ELECTRICAL CONNECTIONS 

All T4x-Series cameras can be connected to a CBX500 connection box using a 

CAB-SCSxx

 

accessory cable. These accessory cables terminate in a 19-pin connector on the camera side 

and in a 25-pin male D-sub connector on the CBX side. 

 

We recommend making system connections through one of the CBX connection boxes since 

they offer the advantages of easy connection, easy device replacement, and filtered reference 

signals. 

 

The table below shows the terminal block connections for the CBX500. 

 

CBX500 Terminal Block Connectors 

Input Power 

Vdc 

Power Supply Input V 

GND 

Power Supply Input Voltage - 

Earth 

Protection Earth Ground (See Caution) 

Inputs 

+V 

Power Source – External Trigger 

I1A 

External Trigger A (polarity insensitive) 

I1B 

External Trigger B (polarity insensitive) 

-V 

Power Reference – External Trigger 

+V 

Power Source – Inputs 

I2A 

Input 2 A (polarity insensitive) 

I2B 

Input 2 B (polarity insensitive) 

I3A 

NOT USED 

I4A 

NOT USED 

I34B 

NOT USED 

-V 

Power Reference – Inputs 

Shield 

Shield 

Network Cable Shield 

Содержание T4 Series

Страница 1: ...T4x Series QuickStart Guide Publication 821002560...

Страница 2: ...ger and Impact are trademarks of Datalogic Automation S r l All other brand and product names mentioned herein are for identification purposes only and may be trademarks or registered trademarks of th...

Страница 3: ...m and click on one of the following links for further information PRODUCTS Search through the links to arrive at your product page which describes specific Info Features Applications Models Accessorie...

Страница 4: ...may cause radio interference in which case the user may be required to take adequate measures FCC COMPLIANCE Modifications or changes to this equipment without the expressed written approval of DLA co...

Страница 5: ...E CAMERA The first step to perform is to assemble any accessories that make up the T4x Series camera A lens must be used A strobe or other external illuminator may be required CAUTION The camera must...

Страница 6: ...out shown in the figure below an EtherNet host is connected to the camera The camera can use an external trigger to signal image acquisition The CBX is used to facilitate the connection between the ca...

Страница 7: ...rnal trigger device photocell and additional I O connections Use the CAB GE0x for the Gigabit Ethernet connection to the host NOTE The T4x Series does not support sourcing power towards the CBX in ord...

Страница 8: ...ks during image and flash memory access 8 BUTTON Camera Reset See Note below To trigger the Camera Button event press and release the button Internal software event trigger only Note Camera Reset will...

Страница 9: ...es can be installed to operate in different positions using the body mounting bracket shown in Figure 3 Use the fourteen screw holes M4 on the body of the camera for custom mounting solutions The diag...

Страница 10: ...ions through one of the CBX connection boxes since they offer the advantages of easy connection easy device replacement and filtered reference signals The table below shows the terminal block connecti...

Страница 11: ...tion Manual POWER SUPPLY NOTE The T4x Series does not support sourcing power towards the CBX through the CBX power from device source jumper setting Power must be supplied to the CBX as shown below To...

Страница 12: ...aximum cable length must be less than 15 m 49 2 ft Figure 5 RS232 Main Interface Connections Using Hardware Handshaking INPUTS There are two optocoupled polarity insensitive inputs available on the ca...

Страница 13: ...g diagrams EXTERNAL TRIGGER INPUT CONNECTIONS USING CBX POWER CAUTION Power is available directly to the Input Device independently from the Power Supply Switch inside the CBX EXTERNAL TRIGGER Camera...

Страница 14: ...Signal V VCC I1A I1B Figure 9 NPN External Trigger Using External Power INPUT 2 CONNECTIONS INPUT 2 CONNECTIONS USING CBX POWER CAUTION Power is available directly to the Input Device independently f...

Страница 15: ...used either to signal the data collection result or to control an external lighting system The electrical features of the two outputs are the following VCE 30 Vdc max ICE 40 mA continuous max 130 mA p...

Страница 16: ...Using CBX Power Figure 15 Open Collector Output Using CBX Power OUTPUT CONNECTIONS USING EXTERNAL POWER Figure 16 Output Open Emitter Using External Power Figure 17 Output Open Collector Using Extern...

Страница 17: ...hed by the procedures described in the Impact Reference Guide VPM is used to configure the camera for specific applications and provides the tools to create vision programs VPM SYSTEM REQUIREMENTS To...

Страница 18: ...eted you can start VPM Changing the Camera s IP Address 1 Connect to the device with VPM 2 Select the Settings tab 3 Click the General System Object 4 Select the General radio button 5 Enter the desir...

Страница 19: ...the front of the processor DO NOT change any of the other Local Area Connections Changing any other connection can cause the M Series cameras to stop functioning 1 In the Start menu click on Control...

Страница 20: ...ART GUIDE 20 5 In the list of items select Internet Protocol Version 4 TCP IPv4 then click Properties 6 Select Use the following IP address 7 Enter the desired IP address 8 Click OK to close all the o...

Страница 21: ...ate T40 60 T47 15 T49 15 ENVIRONMENTAL FEATURES Operating Temperature 1 0 to 45 C 32 to 113 F Storage Temperature 20 to 70 C 4 to 158 F Max Humidity 90 non condensing Vibration Resistance 1 5 mm 5 to...

Страница 22: ...www datalogic com...

Отзывы: