Manuale Istruzioni
Serie SE4-PLUS
60
EN ISO 138
49-1
EN 954-1
EN IEC 61508
EN IEC 62061
Prob. of dan
ger
failure/hour
Life span
Mean Time to D
a
ngerous
F
a
ilur
e
Average Diagnos
tic
Coverage
Safe Failure F
rac
tion
Hardwa
re F
ault Tolerance
Product PL
CAT SIL
SIL
CL
PFHd
(1/h)
T1
(years)
MTTFd
(years)
DC SFF
HFT
SE4-14-015-PP-S
e 4 3 3
2.78E-09
20 324
99.00% 99.45%
1
SE4-14-030-PP-S
e 4 3 3
2.78E-09
20 324
99.00% 99.45%
1
SE4-14-045-PP-S
e 4 3 3
2.78E-09
20 324
99.00% 99.45%
1
SE4-14-060-PP-S
e 4 3 3
2.78E-09
20 324
99.00% 99.45%
1
SE4-14-075-PP-S
e 4 3 3
2.78E-09
20 324
99.00% 99.45%
1
SE4-14-090-PP-S
e 4 3 3
2.78E-09
20 324
99.00% 99.45%
1
SE4-14-105-PP-S
e 4 3 3
2.78E-09
20 324
99.00% 99.45%
1
SE4-14-120-PP-S
e 4 3 3
2.78E-09
20 324
99.00% 99.45%
1
SE4-30-015-PP-S
e 4 3 3
2.78E-09
20 324
99.00% 99.45%
1
SE4-30-030-PP-S
e 4 3 3
2.78E-09
20 324
99.00% 99.45%
1
SE4-30-045-PP-S
e 4 3 3
2.78E-09
20 324
99.00% 99.45%
1
SE4-30-060-PP-S
e 4 3 3
2.78E-09
20 324
99.00% 99.45%
1
SE4-30-075-PP-S
e 4 3 3
2.78E-09
20 324
99.00% 99.45%
1
SE4-30-090-PP-S
e 4 3 3
2.78E-09
20 324
99.00% 99.45%
1
SE4-30-105-PP-S
e 4 3 3
2.78E-09
20 324
99.00% 99.45%
1
SE4-30-120-PP-S
e 4 3 3
2.78E-09
20 324
99.00% 99.45%
1
SE4-30-135-PP-S
e 4 3 3
2.78E-09
20 324
99.00% 99.45%
1
SE4-30-150-PP-S
e 4 3 3
2.78E-09
20 324
99.00% 99.45%
1
SE4-30-165-PP-S
e 4 3 3
2.78E-09
20 324
99.00% 99.45%
1