6.7.1. Stand-Alone Master
The Master unit can be used separately from the Slave unit (the
contrary is not possible). For correct device functioning, connect
the specific electrical terminations to the M12 5-pole connectors
assigned to the Master/Slave connection.
The terminations are supplied together with the Master unit and
provide-out the following connection:
3
4
2
1
LINE B
LINE A
5
6.7.2. Alignment
The alignment procedure of the single unit (Master or Slave) is
not very different from the standard procedure described in
section 5.1.
The LEDs, in the Cascade configuration, signal alignment only
when the Master and Slave are both correctly aligned.
It is thus impossible to distinguish whether the single unit, Master
or Slave, is not aligned correctly. We suggest consequently to
divide the procedure in two different phases:
Master alignment:
carry-out the alignment procedure of only
the Master unit according to the standard procedure
(see
section 5.1)
, connecting the electrical terminations instead of the
Slave unit.
In presence of correct alignment, fix the Master and remove
power supply.
Replace the electrical termination with the Master/Slave
connection cables.
Slave alignment:
the standard alignment procedure can now
be carried-out for the Slave unit. Aligned correctly the Master
unit, the operator is certain that all LED signals are referred to
the Slave alignment.