S8-PR/MR…U
Luminescence sensor
INSTRUCTION MANUAL
CONTROLS
OUTPUT LED (yellow)
The yellow LED ON indicates the output status.
READY LED (green)
The green LED ON indicates the powering status.
SET PUSH-BUTTON
A long pressure on the push-button activates the teach procedure.
The REMOTE input allows the external control of the SET push-button.
DARK/LIGHT TRIMMER
The light/dark mode is selected by a monoturn trimmer.
Please refer to the “SETTING” paragraph to get the correct setting procedure.
WARNING:
the maximum mechanical rotation range of the trimmer is 240°.
Do not force over of the maximum and minimum positions.
INSTALLATION
S8-PR:
The sensor can be positioned by means of the two housing
holes using two screws (M3x18 or longer, 0.8Nm maximum
tightening torque) with washers.
S8-MR:
The sensor can be positioned by means of the
two threaded holes using two screws (M3x14 or
longer, 0.8Nm maximum tightening torque) with
washers.
Various orientable fixing brackets to ease the
sensor positioning are available (please refer to
the accessories listed in the general catalogue).
The operating distance is measured from
the front surface of the sensor optics.
CONNECTIONS
M8 connector
Pig-tail with M12 connector
TECHNICAL DATA
S8-PR…U
S8-MR…U
Power supply:
12 … 30 VDC Class 2 (Type 1 for S8-MR) UL508
Ripple:
2 Vpp max.
Current consumption
(output current excluded):
30 mA max
Outputs:
PNP or NPN N.O.; 30 VDC max. (short-circuit protection)
Pull-down/up resistance = 47 K
Output current:
100 mA (overload protection)
Output saturation voltage:
2 V
Response time:
250
s / 1 ms
Switching frequency:
500Hz / 2 kHz (according to sensitivity)
Emission type:
LED UV (375 nm)
Spot dimension:
Ø 2 mm a 15 mm
Operating distance (typical values):
10…30 mm
LIGHT/DARK selection:
Mono-turn trimmer
Indicators:
OUTPUT LED (YELLOW) / READY LED (GREEN)
Operating temperature:
-10 … 55 °C
Storage temperature:
-20 … 70 °C
Dielectric strength:
: 1500 VAC 1 min. between electronics and housing
Insulating resistance:
>20 M
500 Vdc between electronics and housing
Ambient light rejection:
according to EN 60947-5-2
Vibrations:
0.5 mm amplitude, 10 … 55 Hz frequency, for each axis (EN60068-2-6)
Housing material:
ABS (S8-PR) / INOX AISI 316L (S8-MR)
Lens material:
Window in glass; lens in PC (S8-PR) / window in PMMA (S8-MR)
Mechanical protection:
IP67 (S8-PR) / IP67, IP69K (S8-MR)
Connections:
M8 4-pole connector /
150 mm
4 mm cable with M12 4-pole connector (S8-PR pig-tail vers.)
Weight:
12 g. max. (S8-PR connector vers.) / 50 g. max.pig-tail (S8-PR pig-tail vers.)
70 g. max (S8-MR connector vers.)
AtEx 2014/34/EU:
II 3G EX nA II T6 ;
II 3D EX tD A22 IP67 T85°C
SETTINGS
LIGHT/DARK MODE SETTING
LIGHT mode setting
Rotate trimmer in an anti-clockwise direction to set the LIGHT
mode (output ON on fluorescent mark).
DARK mode setting
Rotate trimmer in a clockwise direction to set the DARK mode
(output ON on background).
EASY TOUCH ACQUISITION
Place mark in front of the sensor spot and press
SET until the green READY LED turns off.
If the READY LED turns permanently ON the
acquisition was successful.
If the LED blinks slowly the acquisition failed due
to insufficient signal.
Press SET and the sensor returns to the previous
setting.
If the Easy Touch acquisition fails due to
insufficient signal, try using Mark-Background
procedure described below.
MARK-BACKGROUND ACQUISITION
Mark acquisition
Place mark in front of the sensor spot and press
SET until the green READY LED turns on again
(3 sec).
Background acquisition
Place background in front of the sensor spot and
press SET again.
If the READY LED turns permanently ON the
acquisition was successful.
If the LED blinks slowly the acquisition failed due
to insufficient contrast.
Press SET and the sensor returns to the previous
setting.
During detection if the luminescence is very low, the sensor increase his
sensitivity with a frequency of 500Hz ( LED READY green blinks two times at
the end of teach procedure).
OTHER FUNCTIONS
MAXIMUM SENSITIVITY WITH MAXIMUM FREQUENCY
SETTING
To set maximum sensitivity with maximum frequency, press SET
push-button for 5 sec. with LED READY green turns off again.
REMOTE INPUT
The REMOTE signal carries-out acquisition functions without
using the SET push-button.
The REMOTE wire connected to +VDC is equal to pressing the
SET pus-button, connected to GND or not connected is equal to
not pressing the SET push-button.
DIMENSIONS
The sensors are NOT safety devices, and so MUST NOT be used in the safety control of
the machines where installed.
Datalogic S.r.l.
Via S. Vitalino 13 - 40012 Calderara di Reno - Italy
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com
Helpful links at www.datalogic.com:
Contact Us,
Terms and Conditions,
Support
.
The warranty period for this product is 36 months. See General Terms and Conditions of Sales for
further details.
Under current Italian and European laws, Datalogic is not obliged to take care of product
disposal at the end of its life. Datalogic recommends disposing of the product in compliance with
local laws or contacting authorised waste collection centres.
© 2013 - 2017 Datalogic S.p.A. and/or its affiliates
ALL RIGHTS RESERVED.
Without limiting the
rights under copyright, no part of this documentation may be reproduced, stored in or introduced into a
retrieval system, or transmitted in any form or by any means, or for any purpose, without the express
written permission of Datalogic S.p.A. and/or its affiliates. Datalogic and the Datalogic logo are registered
trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. All other trademarks
and brands are property of their respective owners. Datalogic reserves the right to make modifications
and improvements without prior notification.
821002553 Rev. C
S8-PR
EASY TOUCH acquisition
VDC
REM
OTE
GND
1s
Maximum sensitivity
VDC
REM
OTE
GND
5s
Mark acquisition
VDC
REM
OTE
GND
3s
Background acquisition
LIGHT
DARK
S8-MR