56
PowerScan
®
RF
Scanner
Prefix, Suffix, and Label ID
The table below shows examples of how Prefix, Suffix, and Label ID
characters can be applied. The third column contains the label data,
while the first, second, fourth and fifth columns contain the additional
characters added by way of the Prefix, Label ID as Prefix, Label ID as
Suffix, and Global Suffix respectively. The last column shows the
resulting data that will be transmitted when the additional characters
are applied.
Table 5. Prefix, Suffix, Label ID Examples
NOTE
Using this feature requires a thorough understand-
ing of your specific system requirements. If you
have questions or need assistance with these fea-
tures, call your system specialist or Datalogic tech-
nical support.
Global
Prefix
(00 = No
Char)
Label ID as
Prefix
Label Data
Label ID as
Suffix
Global Suffix
(00 - No
Char)
1st
Char
2nd
Char
1st
Char
2nd
Char
(Examples)
1st
Char
2nd
Char
1st
Char
2nd
Char
Resulting Label
Format
00
00
None
0998875
None
00
00
0998875
P
Q
None
0011223344
None
000
000
PQ0011223344
00
00
F
F
00210126
None
00
00
FF00210126
P
Q
A
00
a
a.
No second character
00210126
None
00
00
PQA00210126
00
00
None
$99.95
%
00
a
00
00
$99.95%
P
Q
None
998875
%
00
a
00
00
PQ998875%
00
00
None
101234567891
None
S
W
101234567891SW
P
Q
None
Code39Test
None
S
W
PQCode39TestSW
00
00
E
00
a
Code128
None
S
00
ECode128S
P
00
E
F
0998875
None
S
W
PEF09988875SW
00
00
None
0998875
F
F
S
W
0998875FFSW
P
Q
None
0011223344
F
00
a
S
W
PQ0011223344FSW
Содержание PowerScan RF
Страница 1: ...PowerScan RF Programming Guide ...
Страница 6: ...iv Magellan 8300 8400 ...
Страница 12: ...6 PowerScan RF Scanner Figure 1 Removing Replacing the Interface Cable b c a ...
Страница 34: ...28 PowerScan RF Scanner Baud Rate 19200 Baud Rate 38400 END Transmit Scanner Configuration to Base Station ...
Страница 47: ...RF Programming Manual 41 H I J END Transmit Scanner Configuration to Base Station ...
Страница 89: ...RF Programming Manual 83 Digits 0 1 2 3 4 5 6 7 8 9 ...
Страница 95: ...RF Programming Manual 89 Digits 0 1 2 3 4 5 6 7 8 9 ...
Страница 104: ...98 PowerScan RF Scanner Digits 0 1 2 3 4 5 6 7 8 9 ...
Страница 114: ...108 PowerScan RF Scanner Digits 0 1 2 3 4 5 6 7 8 9 ...
Страница 133: ...RF Programming Manual 127 Deactivate for EAN 8 END ...
Страница 136: ...130 PowerScan RF Scanner END Digits 0 1 2 3 4 5 6 7 ...
Страница 144: ...138 PowerScan RF Scanner Digits 0 1 2 3 4 5 6 7 8 9 ...
Страница 153: ...RF Programming Manual 147 Digits 0 1 2 3 4 5 6 7 8 9 ...
Страница 161: ...RF Programming Manual 155 RF Beeper Volume 1 RF Beeper Volume 2 RF Beeper Volume 3 END ...
Страница 168: ...162 PowerScan RF Scanner 2 Retries 3 Retries recom mended 4 Retries 5 Retries 6 Retries 7 Retries 8 Retries 9 Retries ...
Страница 200: ...194 PowerScan RF Scanner 9 0 A B C D E F ...
Страница 208: ...202 PowerScan RF Scanner NOTES ...
Страница 213: ...RF Programming Manual 207 NOTES ...
Страница 214: ...208 PowerScan RF Scanner NOTES ...