Outputs
Product Reference Guide
79
Outputs
CAUTION
Three general purpose outputs are available and their meaning can be defined
by the user. They are typically used either to signal the data collection result or
to control an external lighting system.
CBX100/500
Description
+V
Power Source - Outputs
O1+
Output 1 + opto-isolated and polarity sensitive
O1-
Output 1 - opto-isolated and polarity sensitive
O2+
Output 2 + opto-isolated and polarity sensitive
O2-
Output 2 - opto-isolated and polarity sensitive
O3A
Output 3 non opto-isolated (only available on CBX500)
-V
Power Reference - Outputs
The electrical features of the outputs are the following:
Outputs 1 and 2
Output 3
V
CE
= 30 Vdc max.
Reverse-Polarity and Short-Circuit Pro-
tected
I
CE
= 40 mA continuous max.; 130 mA
pulsed max.
V
OUT
(I
LOAD
= 0 mA) max = 30 Vdc
V
CE saturation
= 1 Vdc max. @ 10 mA
V
OUT
(I
LOAD
= 100 mA) max = 3 Vdc
P
D
= 90 mW Max. @ 50 °C ambient temp.
I
LOAD
max = 100 mA
By default, Output 1 is associated with the No Read event, which activates when
the code(s) signaled by the external trigger are not decoded, and Output 2 is
associated with the Good Read event, which activates when all the selected codes
are correctly decoded.
The output signals are fully programmable being determined by the configured
Activation/Deactivation events, Deactivation Timeout or a combination of the
two. Refer to the DL.CODE parameters Help On Line for further details.
When
Outputs 1
and 2 are connected through the CBX connection box, they become
opto-isolated and polarity sensitive and acquire the electrical characteristics listed
below. To function correctly, they require setting the Output Line Type configuration
parameters to NPN for the respective output. The hardware connection to the CBX
can be either NPN or PNP.
Содержание Matrix 300N
Страница 1: ...Matrix 300N Product Reference Guide Image Based Reader...
Страница 72: ...Installation 56 Matrix 300N Figure 28 Mounting Bracket Overall Dimensions mm inch...
Страница 86: ...CBX Electrical Connections 70 Matrix 300N Figure 43 ID NET Network Connections with Common Power Branch Network...
Страница 87: ...ID NET Interface Product Reference Guide 71 Figure 44 ID NET Network Connections with Common Power Star Network...
Страница 91: ...Inputs Product Reference Guide 75 Figure 48 NPN External Trigger Using Matrix 300N Power...
Страница 153: ...Reader Configuration Product Reference Guide 137 Figure 84 Decoding Results OK...
Страница 180: ...ID NET Master ID NET Slave 1 ID NET Slave 1 Software Configuration 164 Matrix 300N...
Страница 182: ...Software Configuration 166 Matrix 300N Open the cloned application job...
Страница 216: ...DPM Data Matrix and QR codes on metal surfaces Non polarized Polarized Illuminators 200 Matrix 300N...
Страница 246: ......
Страница 247: ......