![Datalogic Matrix 300N Скачать руководство пользователя страница 83](http://html1.mh-extra.com/html/datalogic/matrix-300n/matrix-300n_product-reference-manual_3706111083.webp)
ID-NET Interface
Product Reference Guide
67
ID-NET Interface
CBX100/500
Description
Shield
Network Cable Shield
ID+
ID-NET Network Data +
ID-
ID-NET Network Data -
REF
Network Reference
ID-NET Cables
These instructions are referred to
Figures
and
• The general cable type specifications are: CAT5 twisted pair + additional
CAT5 twisted pair, shielded cable AWG 24 (or AWG 22) stranded flexible.
We recommend using DeviceNet cables (drop or trunk type) to the following
reference standards:
AN50325 – IEC 62026
UL STYLE 2502 80°C 30V
• Cable Shield MUST be connected to earth ground ONLY at the Master.
• NEVER use ID-NET cable shield as common reference.
• The ID-NET max cable length depends on the baudrate used, (see the Bau-
drate Table below).
• For Common Power Connections use only 2 wires (ID+ and ID-).
• DC Voltage Power cable (Vdc – GND) should be handled as a signal cable
(i.e. do not put it together with AC cable):
• Wire dimensioning must be checked in order to avoid voltage drops
greater than 0.8 Volts.
• Cable should lie down as near as possible to the ID-NET cable (avoiding
wide loops between them).
• Reader's chassis may be connected to earth.
• Network inside the same building.
Baudrate Table
Baudrate
125 kbps
250 kbps
500 kbps
1 Mbps
Cable Length
1200 m
900 m
700 m
*
*
Application dependent, contact your Datalogic representative for details.
NOTE
The default ID-NET baudrate is 500 kbps. Lower ID-NET baudrates allow longer cable
lengths.
Содержание Matrix 300N
Страница 1: ...Matrix 300N Product Reference Guide Image Based Reader...
Страница 72: ...Installation 56 Matrix 300N Figure 28 Mounting Bracket Overall Dimensions mm inch...
Страница 86: ...CBX Electrical Connections 70 Matrix 300N Figure 43 ID NET Network Connections with Common Power Branch Network...
Страница 87: ...ID NET Interface Product Reference Guide 71 Figure 44 ID NET Network Connections with Common Power Star Network...
Страница 91: ...Inputs Product Reference Guide 75 Figure 48 NPN External Trigger Using Matrix 300N Power...
Страница 153: ...Reader Configuration Product Reference Guide 137 Figure 84 Decoding Results OK...
Страница 180: ...ID NET Master ID NET Slave 1 ID NET Slave 1 Software Configuration 164 Matrix 300N...
Страница 182: ...Software Configuration 166 Matrix 300N Open the cloned application job...
Страница 216: ...DPM Data Matrix and QR codes on metal surfaces Non polarized Polarized Illuminators 200 Matrix 300N...
Страница 246: ......
Страница 247: ......