![Datalogic Matrix 300N Скачать руководство пользователя страница 81](http://html1.mh-extra.com/html/datalogic/matrix-300n/matrix-300n_product-reference-manual_3706111081.webp)
Main Serial Interface
Product Reference Guide
65
Main Serial Interface
CAUTION
The signals relative to the following serial interface types are available on the
CBX spring clamp terminal blocks.
The main serial interface type and its parameters (baud rate, data bits, etc.) can
be defined by the user via DL.CODE software. For more details refer to the Help
On Line page of the Reading Phase step (Channels) in DL.CODE.
Details regarding the connections and use of the interfaces are given in the next
paragraphs.
RS232 Interface
The RS232 interface is generally used for Point-to-Point connections. When it is
connected to the host computer it allows transmission of code data.
The following pins are used for RS232 interface connection:
CBX100/500
Description
TX
Transmit Data
RX
Receive Data
SGND
Signal Ground
It is always advisable to use shielded cables. The overall maximum cable length
must be less than 15 m (49.2 ft).
User Interface
Reader
RX
TX
SGND
TXD
RXD
SGND
Figure 38 - RS232 Main Interface Connections
Do not connect to the Main Interface spring clamp terminals if using Host Interface
Modules (Fieldbus) with the CBX500.
Содержание Matrix 300N
Страница 1: ...Matrix 300N Product Reference Guide Image Based Reader...
Страница 72: ...Installation 56 Matrix 300N Figure 28 Mounting Bracket Overall Dimensions mm inch...
Страница 86: ...CBX Electrical Connections 70 Matrix 300N Figure 43 ID NET Network Connections with Common Power Branch Network...
Страница 87: ...ID NET Interface Product Reference Guide 71 Figure 44 ID NET Network Connections with Common Power Star Network...
Страница 91: ...Inputs Product Reference Guide 75 Figure 48 NPN External Trigger Using Matrix 300N Power...
Страница 153: ...Reader Configuration Product Reference Guide 137 Figure 84 Decoding Results OK...
Страница 180: ...ID NET Master ID NET Slave 1 ID NET Slave 1 Software Configuration 164 Matrix 300N...
Страница 182: ...Software Configuration 166 Matrix 300N Open the cloned application job...
Страница 216: ...DPM Data Matrix and QR codes on metal surfaces Non polarized Polarized Illuminators 200 Matrix 300N...
Страница 246: ......
Страница 247: ......