RAPID CONFIGURATION
21
1
STEP 6
– DEVICE CONFIGURATION
Image Setup
for Software Adjustable Focus Models
(Liquid Lens)
NOTE:
For Fixed Focus models go to page 27 then continue with
Code
Setup
To begin configuration, the reader must be correctly mounted at the correct reading distance
for your application so that its Field of View covers the application reading area.
1. From the Task Area select Open Device Configuration.
2. The Open Device Configuration window opens showing the list of currently saved
configurations (jobs) saved on the device. For new devices, the only saved job is the
Default configuration. Click OK. The device enters run mode and begins acquiring
images.
3. Place the
Grade A Barcode Test Chart
in the reading area. Once positioned, stop
image acquisition by clicking on the Pause button.