TROUBLESHOOTING
141
9
9 TROUBLESHOOTING
9.1 GENERAL GUIDELINES
When wiring the device, pay careful attention to the signal name (acronym) on the
CBX100/500 spring clamp connectors (chp. 4). If you are connecting directly to the
Matrix 210N 25-pin male D-sub connector pay attention to the pin number of the signals
(Appendix A).
If you need information about a certain reader parameter you can refer to the DL.CODE
help on line. Connect the device and click on the link to the parameter you’re interested.
If you’re unable to fix the problem and you’re going to contact your local Datalogic office or
Datalogic Partner or ARC, we suggest providing (if possible): Application Program version,
Parameter Configuration file, Serial Number and Order Number of your reader. You can
get most of this information while DL.CODE is connected to the reader.
TROUBLESHOOTING GUIDE
Problem
Suggestion
DL.CODE Installation:
Autorun or Start.hta doesn’t
run
Check Windows settings to see if Autorun is disabled.
Associate the file type .hta with the Microsoft HTML
Application host
mshta.exe
in Windows\System32.
Power ON:
the “POWER” LED is not lit.
Is power connected?
If using a power adapter (like PG6000), is it connected
to wall outlet?
If using rail power, does rail have power?
If using CBX, does it have power (check switch and
LED)?
Check if you are referring to the 25-pin connector or to
the CBX spring clamp connectors.
Measure Voltage either at pin
13
and pin
25
(for 25-pin
connector) or at spring clamp
Vdc
and
GND
(for CBX).
One Shot or Phase Mode
using the Input 1 (External
Trigger) or Input 2:
the ”TRIGGER” LED is not
blinking while the External
Trigger is switching.
Check if you are referring to the 25-pin connector or to
the CBX spring clamp connectors.
Is the sensor connected to the Input 1 or Input 2?
Is power supplied to the photo sensor?
For NPN configuration, is power supplied to one of the
two I1 or I2 signals (A or B)?
For PNP configuration, is one of the two I1 or I2 signals
grounded (A or B)?
Are the photo sensor LEDS (if any) working correctly?
Is the sensor/reflector system aligned (if present)?
On the Reading Phase step check the Input 1 or Input 2
Debounce Filter
parameter setting.
On the Reading Phase step check the settings for
Acquisition
Trigger,
Reading
Phase-ON,
and
Reading Phase-OFF
parameters.
Содержание Matrix 210N
Страница 1: ...REFERENCE MANUAL Matrix 210N...
Страница 76: ...MATRIX 210N REFERENCE MANUAL 64 4 Figure 46 ID NET Network Connections with isolated power blocks...
Страница 77: ...CBX ELECTRICAL CONNECTIONS 65 4 Figure 47 ID NET Network Connections with Common Power Branch Network...
Страница 78: ...MATRIX 210N REFERENCE MANUAL 66 4 Figure 48 ID NET Network Connections with Common Power Star Network...
Страница 82: ...MATRIX 210N REFERENCE MANUAL 70 4 Figure 52 NPN External Trigger Using Matrix 210N Power NPN...
Страница 131: ...SOFTWARE CONFIGURATION 119 7 ID NET Slave 2 ID NET Master ID NET Slave 1...
Страница 133: ...SOFTWARE CONFIGURATION 121 7 Open the cloned application job...
Страница 167: ......