RAPID CONFIGURATION
11
1
NOTE:
You can always exit from any X-PRESS function at any time by
pressing the X-PRESS push button once. After a short delay the procedure is
cancelled.
NOTE:
If you have used this procedure to configure Matrix 210N go to step
7.
Reset Reader to Factory Default Environment (Optional)
If it ever becomes necessary to reset the reader
’s Environment parameters to their factory
default values, you can perform this procedure by holding the X-PRESS push button pressed
while powering up the reader.
You must keep the X-PRESS push button pressed until all
LEDs blink simultaneously for about 3 seconds. Release and re-press the button
during this LED blinking sequence
.
All the device’s Environment parameters are reset including the default IP Address. The
Matrix 210N emits 3 high pitched beeps and after a few seconds enters run mode.
Any previously saved configurations on the device will remain in memory, but the Default
configuration is set as the startup configuration.
NOTE:
If you release the button while the LEDs are all on continuously (after
the blinking phase), the reader will enter the Loader program sequence and
the LEDs will begin to cycle through various patterns. Just cycle power to
return to run mode.
Содержание Matrix 210N
Страница 1: ...REFERENCE MANUAL Matrix 210N...
Страница 76: ...MATRIX 210N REFERENCE MANUAL 64 4 Figure 46 ID NET Network Connections with isolated power blocks...
Страница 77: ...CBX ELECTRICAL CONNECTIONS 65 4 Figure 47 ID NET Network Connections with Common Power Branch Network...
Страница 78: ...MATRIX 210N REFERENCE MANUAL 66 4 Figure 48 ID NET Network Connections with Common Power Star Network...
Страница 82: ...MATRIX 210N REFERENCE MANUAL 70 4 Figure 52 NPN External Trigger Using Matrix 210N Power NPN...
Страница 131: ...SOFTWARE CONFIGURATION 119 7 ID NET Slave 2 ID NET Master ID NET Slave 1...
Страница 133: ...SOFTWARE CONFIGURATION 121 7 Open the cloned application job...
Страница 167: ......