CBX ELECTRICAL CONNECTIONS
75
4
4.7 EXTERNAL LIGHTING SYSTEMS
If an External Illuminator is used, it can be powered from the CBX connection box. It must be
connected to the
Vdc
and
GND
terminal clamps.
CAUTION:
Power is available directly to the Illuminator, independently from
the Power Supply Switch inside the CBX. Disconnect the power supply when
working inside the CBX.
In the case of the LT-700 illuminator, one of the available digital outputs must be connected
as the control signal. In DL.CODE, configure the Output Line Function parameter to one of
the External Illuminator selections: Always On or Strobed.
Control Signal for LT-700
illuminators
Power to External
Illuminator
Figure 61
– External Lighting System Connections
Below is a table summarizing the External Illuminator wiring and power requirements:
Illuminator
Wire Color
CBX/Matrix Signal
Meaning
LT-700
Red
Vdc
10 to 30 Vdc
Black
GND
Ground
White
Earth
Shield/Earth Ground
Green
O1- or O2-
Control Signal -
Yellow
O1+ or O2+
Control
Содержание Matrix 210N
Страница 1: ...REFERENCE MANUAL Matrix 210N...
Страница 76: ...MATRIX 210N REFERENCE MANUAL 64 4 Figure 46 ID NET Network Connections with isolated power blocks...
Страница 77: ...CBX ELECTRICAL CONNECTIONS 65 4 Figure 47 ID NET Network Connections with Common Power Branch Network...
Страница 78: ...MATRIX 210N REFERENCE MANUAL 66 4 Figure 48 ID NET Network Connections with Common Power Star Network...
Страница 82: ...MATRIX 210N REFERENCE MANUAL 70 4 Figure 52 NPN External Trigger Using Matrix 210N Power NPN...
Страница 131: ...SOFTWARE CONFIGURATION 119 7 ID NET Slave 2 ID NET Master ID NET Slave 1...
Страница 133: ...SOFTWARE CONFIGURATION 121 7 Open the cloned application job...
Страница 167: ......