112.5 x 152 x 102
1.5 kg
Aluminum Alloy
YellowRAL1003
PC
Acrylic
Max 95% non-condensing
According to
IEC 61496-1 5.4.2
IEC 61496-3 5.4.2; 4.3.1; 5.4.4.3
IP65
-10 to +50 °C
-20 to +70 °C
According to
IEC 61496-1 4.3.3.1; 5.4.4.1
IEC 60068-2-6;
Frequency: from 10 Hz to 55 Hz; Scan Speed
1 octave/min;
Range: 0,35 mm ± 0,05 mm
According to
IEC 61496-1 4.3.3.2; 5.4.4.2
IEC 60068-2-27; Acceleration: 10 g; Pulse
Duration: 16 ms; Number of Shocks: 1000 ±
10
(
for each of the three mutually perpendicular
axes
)
IEC 61496-3 5.4.4.1-3
IEC 60068-2-75; Hammer test
905 nm
3 ns
8 mw
CLASS 1 (EN 60825-1:2014)
0.12 °
INSTRUCTION MANUAL
119
MECHANICAL DATA
Dimensions (W × H × D)
Weight (including system plug)
Housing material
Housing color
Optics cover material
Optics cover surface
ENVIRONMENTAL DATA
Humidity
Enclosure rating (IP)
a
a. The enclosure rating is valid if all the safety laser scanner M12 connectors are sealed using an IP65 rated
connection cable or higher or if not connected by using a protective cap.
Operating temperature
b
b.
It is recommended to allow for a 15-minute warm-up from a cold start at a temperature < 5 °C before
using the device in normal operation.
Storage temperature
Vibration resistance
Shock resistance
OPTICAL DATA
Wavelength
Pulse duration
Average output power
Laser class/Laserklass
Divergence of collimated beam
Содержание Laser Sentinel
Страница 1: ...Laser Sentinel INSTRUCTION MANUAL Safety Laser Scanner ...
Страница 18: ...GENERAL VIEW xviii SAFERY LASER SCANNER ...
Страница 140: ...122 SAFERY LASER SCANNER APPENDIX B OVERALL DIMENSIONS LASER SENTINEL STAND ALONE MODEL ...
Страница 141: ...LASER SENTINEL MASTER MODEL INSTRUCTION MANUAL 123 LASER SENTINEL MASTER MODEL LASER SENTINEL SLAVE MODEL ...
Страница 149: ......
Страница 150: ......
Страница 151: ......