8 mm
10 mm
20 mm
1.8% - “1000%”
- 30% of nominal optic power
Type 3 (EN 61496-1)
SIL 2 (IEC 61508)
Category 3 (EN ISO 13849-1)
SILCL 2 (EN 62061)
PL d (EN ISO 13849-1)
6.38 x 10
-8
97.58 %
61 Years
20 years (EN ISO 13849-1)
1
OSSD in OFF State (open circuit: I OSSD = 0)
<= Response Time
M12 male type A connector (8/12/17 poles)
M12 male type D connector (4 poles)
M12 male type A connector (8 poles)
INSTRUCTION MANUAL
121
LIGHT BEAM DIAMETER
At front screen
At middle field distance
At max distance
Detectable remission
Maximum homogeneous contamination of the
optics cover without preventing the detection
capability
SAFETY DATA
Type
Safety integrity level
Category
SIL claim limit
Performance level
PFHd (mean probability of a dangerous
failure per hour)
SFF
MTTFd
TM (mission time)
HFT (Hardware Fault Tolerance)
State of safety
Response time to malfunction
CONNECTORS
I/O and power
Ethernet to GUI or Data transmission
Master to Slave
Slave to Slave