HORIZONTAL APPLICATION CONFIGURATION
INSTRUCTION MANUAL
5
HORIZONTAL APPLICATION CONFIGURATION
Figure 2 - Static horizontal configuration
The device uses a horizontal protective field (the red area in the figures) to detect the
presence of an object or a person.
The Laser Sentinel will scan the environment surrounding the hazardous point to detect
approaching objects or people. If someone is detected in the safety zone (with a given
detection capability), a stopping signal is sent to the machine by the device. This signal
will stop the machine by putting the OSSDs in OFF state.
In this example a Warning Zone has been defined (yellow zone in the figure) in order to
give a preliminary warning if someone is detected, to prevent operators from acciden-
tally stopping the working process of the machine. The warning signals are sent using
non-safe outputs assigned to the area.
Содержание Laser Sentinel
Страница 1: ...Laser Sentinel INSTRUCTION MANUAL Safety Laser Scanner ...
Страница 18: ...GENERAL VIEW xviii SAFERY LASER SCANNER ...
Страница 140: ...122 SAFERY LASER SCANNER APPENDIX B OVERALL DIMENSIONS LASER SENTINEL STAND ALONE MODEL ...
Страница 141: ...LASER SENTINEL MASTER MODEL INSTRUCTION MANUAL 123 LASER SENTINEL MASTER MODEL LASER SENTINEL SLAVE MODEL ...
Страница 149: ......
Страница 150: ......
Страница 151: ......