DS6500
14
2
The table below gives the pinout of the C-BOX 100 terminal block connectors. Use this
pinout when the DS6500 reader is connected in a network by means of the
C-BOX 100:
C-BOX 100 Terminal Block Connectors
Power
1, 3, 5
VS
2, 4, 6
GND
7, 8
EARTH GROUND
20, 40
Reserved
Inputs
27
EXT TRIG A (polarity insensitive)
28
EXT TRIG B (polarity insensitive)
29
IN 2A (polarity insensitive)
30
IN 2B (polarity insensitive)
31, 33
IN 3A (polarity insensitive)
32, 34
IN 4A (polarity insensitive)
36
IN 3B/IN 4B Reference (polarity insensitive)
Outputs
21 OUT
1+
22 OUT
1-
23 OUT
2+
24 OUT
2-
25
OUT 3A (polarity insensitive)
26
OUT 3B (polarity insensitive)
Auxiliary Interface
35 TX
AUX
37 RX
AUX
38, 39
GND
Main Interface
RS232
RS485
Full-Duplex
RS485
Half-Duplex
20 mA C.L.
(
INT-60 Only)
11, 15
TX232
TX485+
CLOUT+
12, 16
RTS232
TX485-
RTX485-
CLOUT-
17 RX232 RX485+
CLIN+
18 CTS232 RX485-
CLIN-
10, 14, 19
SGND Main Isolated SGND Main Isolated
SGND Main Isolated
9, 13
RS485 Cable Shield RS485 Cable Shield