DS6500
28
2
This interface and the connector pinout (see the following table) are IEEE 802.3 10 BaseT
and IEEE 802.3u 100 Base Tx compliant.
RJ45 Modular Jack Pinout
Pin Name
Function
1
TX +
Transmitted data (+)
2
TX -
Transmitted data (-)
3
RX +
Received data (+)
6
RX -
Received data (-)
4, 5, 7, 8
N.C.
Not connected
Ethernet Interface
The Ethernet interface (NIC) can be used for TCP/IP communication with remote or local
host computer by connecting the scanner to a LAN as well as with a host PC directly
connected to the scanner.
The following is an example of a connection to a LAN through a Hub using a straight through
cable:
DS6500
5
HUB / SWITCH
3
4
2
1
6
5
3
4
2
1
6
7
8
7
8
RX+
TX-
TX+
RX-
n. c.
n. c.
n. c.
n. c.
n. c. = not connected
Figure 48 – Straight Through Cable
The following is an example of direct connection to a PC using an inverted cable:
DS6500
5
HOST PC
3
4
2
1
6
5
1
4
6
3
2
7
8
7
8
RX+
TX-
TX+
RX-
n. c.
n. c.
n. c.
n. c.
n. c. = not connected
Figure 49 – Inverted Cable