AMT58x-EC EtherCAT®
52
NOTE
• If the scaling function is disabled (bit 2
Scaling function
in the
parameter
6000-00 Operating parameters
= 0),
6003-00 Preset
value
must be lower than or equal to the
total hardware
resolution
(i.e.
6501-00 Hardware counts per revolution
6502-00 Hardware number of turns
).
• If the scaling function is enabled (bit 2
Scaling function
in the
parameter
6000-00 Operating parameters
= 1),
6003-00 Preset
value
must be lower than or equal to
6002-00 Total resolution
.
Set Preset value
6003-00 Preset value
(preset = 1000 = 3E8h)
Master Encoder
Cmd specific data
Cmd Index Sub
Data
23 03 60 00 E8 03 00 00
Encoder Master (Set confirmation)
Cmd specific data
Cmd Index Sub
Data
60 03 60 00 00 00 00 00
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]