PARAMETERS LIST
55
4
PARAMETER COMPLETE
PATH SHC
PT
VALUE
Termination Char
Value
/Comms/DeviceNet
/SerialData
/InStrSuffixValue
-
0
Range: 0 to 31
Buffer Flush Enable
/Comms/DeviceNet
/SerialData
/BufFlushEnable
- 1 0
=
Disable
1 = Enable
Buffer Flush Delay
(milliseconds)
/Comms/DeviceNet
/SerialData
/BufFlushDelay
-
0
Range: 8 to 9999
DEVICENET / BUS COMMUNICATION
Data Rate
/Comms/DeviceNet
/BusData/BusRate
- 1 0
=
125K
1 = 250K
2 = 500k
Node Address
(MAC ID)
/Comms/DeviceNet
/BusData/NodeAddr
-
0
Range: 0 to 63
Protocol /Comms/DeviceNet
/BusData/Protocol
- 1 0
=
Polled
1 = Bit Strobe
2 = Change of State
Master Input Area
Size
/Comms/DeviceNet
/BusData/TxMsgSize
-
0
Range: 0 to 254
Master Output Area
Size
/Comms/DeviceNet
/BusData/RxMsgSize
-
0
Range: 0 to 254
PROFIBUS
Data Tx
/Comms/ProfiBus
/ProfiBus
266
1
0 = Disable
1 = Enable
Heartbeat /Comms/ProfiBus
/Heartbeat
-
1
0 = Disable
1 = Enable Unconditioned
2 = Enable Conditioned
Heartbeat Timeout
/Comms/ProfiBus
/HeartbeatTimeOut
-
0
Range: 1 to 3600
Heartbeat Header
String
/Comms/ProfiBus
/heartbeatStart
-
3
Length: 0 to 32
Heartbeat Terminator
String
/Comms/ProfiBus
/HeartbeatStop
-
3
Length: 0 to 32
Send Diagnostic Info /Comms/ProfiBus
/SDSPBUS
-
1
0 = Disable
1 = Enable
Host Heartbeat
/Comms/ProfiBus
/HostHeartbeat
-
1
0 = Disable
1 = Enable
Host Heartbeat
Timeout
/Comms/ProfiBus
/HostHeartbeatTimeOut
-
0
Range: 0 to 3600
PROFIBUS / BUS COMMUNICATION
Node Address
/Comms/ProfiBus
/BusData/NodeAddr
268
0
Range: 0 to 125
Data Flow Control
(up to SW 6.85)
/Comms/ProfiBus
/BusData/FlowControl
269
1
0 = Disable
1 = DPD Driver
2 = DAD Driver
3 = SDP Driver
Содержание 6K-8KA FAMILY