6K-8KA FAMILY HOST MODE PROGRAMMING
34
4
PARAMETER COMPLETE
PATH
SHC
PT VALUE
PROTOCOL INDEX PARAM. / ETH1 / PIUSERSOCKET #N (DEPTH: N = 1 to 3)
Use Socket
/Operating
/ProtocolIndexParameters
/Eth1/PIUserSocket#N
/SockEn
-
1
0 = Disable
1 = Enable Without
Request Message
2 = Enable With
Request Message
Header /Operating
/ProtocolIndexParameters
/Eth1/PIUserSocket#N
/StrSock
-
3
Length: 0 to 1
Terminator /Operating
/ProtocolIndexParameters
/Eth1/PIUserSocket#N
/StpSock
-
3
Length: 0 to 1
Protocol Index
Length
/Operating
/ProtocolIndexParameters
/Eth1/PIUserSocket#N
/PILengthSock
-
1
0 = Length In
Message
1 = Variable length
3 = 3
4 = 4
5 = 5
…
12 = 12
No Index Char
/Operating
/ProtocolIndexParameters
/Eth1/PIUserSocket#N
/NOIndexCharSock
-
3
Length: 0 to 1
Protocol Index
Request Message
/Operating
/ProtocolIndexParameters
/Eth1/PIUserSocket#N
/PIReqMsgSock
-
3
Length: 0 to 32
Distance from
Protocol Index to
Trigger Line (mm)
/Operating
/ProtocolIndexParameters
/Eth1/PIUserSocket#N
/TxPtFromRef_Sock
-
0
Range:0 to 65532
NVS9000 HYBRID SYSTEM SLAVE PARAMETERS
Enable NVS
/Operating/NVSHS/NVS
-
1
0 = Disable
1 = Simple
2 = Advanced
First NVS9000
Number
/Operating/NVSHS
/NVSFirstSlaveNB
-
0
Range: 1 to 31
Number of
NVS9000s in Cluster
/Operating/NVSHS
/NVSNBSlaves
-
0
Range: 0 to 9
Select User Socket
or Serial Port
/Operating/NVSHS
/NVSTransportInt
-
1
1 = User Socket 1
2 = User Socket 2
3 = User Socket 3
4 = Auxiliary Serial Port
5 = Main Serial Port
Select Serial Port
/Operating/NVSHS
/NVSTransportSer
-
1
4 = Auxiliary Serial Port
5 = Main Serial Port