![Datalogic 6K-8KA FAMILY Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/datalogic/6k-8ka-family/6k-8ka-family_programming-manual_511824016.webp)
6K-8KA FAMILY HOST MODE PROGRAMMING
12
3
Using Short Parameter Description (Shortcut)
The '
Set Shortcut
' programming string (based on the short parameter description) must
have the following format:
SS
<space>
SHORTCUT
:
VALUE
<CR><LF>
Where:
SS
:
'Set Shortcut' command
SHORTCUT
: Short Parameter Description (SHC)
VALUE
:
Parameter Value
After entering this command, the device responds with the proper reply message and then
waits for one or more programming strings.
If the programming is correct, the device updates the configuration and confirms with the
following message:
Y
<space>
VALUE
<CR><LF>
Where:
VALUE
:
Parameter Value
If programming contents are wrong (i.e. a typing error in the file) or due to a transmission
error, the device replies with the following message and programming data will not be
updated in this case:
N
<space>
ERRCODE
<CR><LF>
Where:
ERRCODE
:
Error Code (signed DEC value)
For information on Error Codes see the "Error Codes Table" in the Appendix.
Содержание 6K-8KA FAMILY
Страница 1: ...6K 8KA FAMILY Host Mode Programming ...
Страница 4: ...iv ...
Страница 73: ...www datalogic com ...