![Datalogic 6K-8KA FAMILY Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/datalogic/6k-8ka-family/6k-8ka-family_programming-manual_511824012.webp)
6K-8KA FAMILY HOST MODE PROGRAMMING
8
3
Type (Parameter Type)
Parameter type is essential in order to decide the parameter
VALUE
format used in the
programming strings. Types are:
Type 0
: Integer
(Numeric)
Type 1
: Enumeration
Type 2
: String
Type 3
: Binary
String
Type 4
: Floating
Point
The other definitions change according to the parameter type.
Integer (Type = 0)
Range
Minimum and maximum values allowed for the parameter.
Example: Reading Phase
Timeout
parameter (
OPERATING MODES
folder).
Path: /Operating/ONLTimeOut
Shortcut: 79
Type: 0
Label: Timeout
(ms)
Range:
40 to 15.000
Default: 500
The sign can be omitted if the parameter value is not negative.
Enumeration (Type = 1)
Item List
List of the values allowed for the parameter (i.e. 0 = first entry of the list, 1 = second entry of
the list).
Example:
Operating Mode
parameter (
OPERATING MODES
folder).
Path: /Operating/Selection
Shortcut: 31
Type: 1
Label:
Operating Mode Selection
Item List:
0 = On Line
1 = Automatic
3 = Test
4 = Continuous
5 = PackTrack
Default:
0 (Entry 0
On Line)