PROGRAMMING STRINGS
21
3
- 5 -
Set
Min Angle
parameter in
OSCILLATING MIRROR
folder:
Path: /Reading/Oscillating/ContMinAngle
Shortcut: 256
Type: 4
(Floating
Point)
Range:
-2.5 to 37.5
Value: -1.5
The 'Set Parameter' programming string is:
SP<space>/Reading/Oscillating/ContMinAngle:-1.5 <CR><LF>
The 'Set Shortcut' programming string is:
SS<space>256:-1.5<CR><LF>
After entering the programming string, the reader responds with the message:
Y<space>-1.5<CR><LF>
- 6 -
Get value of Digital Output 3
Activation Event
parameter in
DIGITAL OUTPUT LINES
folder:
Path: /IO/Out/Out2/Active
Shortcut: 28
Type: 1
(Enumeration)
Current Value:
2 (Entry 2
Partial Read)
The 'Get Parameter' programming string is:
GP<space>/IO/Out/Out2/Active<CR><LF>
The 'Get Shortcut' programming string is:
GS<space>28<CR><LF>
After entering the programming string, the reader responds with the message:
Y<space>2<CR><LF>