DKG-255 User Manual Firmware V-1.0
- 15 -
The unit continuously monitors abnormal conditions during operation. Programmable alarm limits are
provided for every measured value.
If any fault condition occurs, the related error led turns on and an alarm code is displayed.
ALARM CODE DESCRIPTION
Err1
High Battery Voltage. This alarm occurs if battery voltage is higher than 30VDC.
Err2
Low Battery Voltage. This alarm occurs if battery voltage is below set value.
Err3
MPU Error. This alarm occurs if mpu signal is lost when engine speed is below
600rpm.
Err4
MPU Error. This alarm occurs if mpu signal is lost when engine speed is above
600rpm.
Err5
Shot circuit or overload at actuator output.
Err6
Overspeed.
Hold pressed Up and Down buttons together for 5
seconds to reset errors.
Press Up button to view error codes.
5. PROTECTIONS AND ALARMS