Getting Started
DataDirect Networks StorageScaler 6000 User Guide Rev B
15
2.4 DEM
The StorageScaler 6000 enclosure contains eight (8) top-loadable, hot swappable DEMs. The DEMs
provide the SAS connectivity between the I/O module and the HDDs located within the enclosure. Each
DEM connects to a single port of the HDD based on the location within the enclosure in which it is
installed. Each of the eight DEMS installed in the enclosure has a unique I
2
C and SAS address based on
a DataDirect Network SAS address generation scheme.
2.5 Drive Enclosure Device Addressing
See Appendix A.
2.6 Grounding Checks
The product must only be connected to a power source that has a safety electrical earth connection.
Warning
If more than one product is fitted in a rack, the earth connection to the rack is even more
important, because the rack will then have a high “EARTH LEAKAGE CURRENT” (“TOUCH
CURRENT”).
The earth connection to the rack must be checked before switching on, by an electrical engineer who is
qualified to the appropriate local and National standards to perform the check.