background image

ii

Copyright

Copyright 

©

2001 by Datacom Systems, Inc. All rights reserved. Printed in the United States of America. No part of this publica-

tion may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, pho-
tocopying, recording, or otherwise, without the prior written permission of Datacom Systems, Inc. To obtain this permission,
write to the attention of the Datacom Systems legal department at 9 Adler Drive, East Syracuse, New York 13057-1290, or call
315-463-9541.

Trademark Attribution

DS3 ACTIVE

tap

, DS3

switch

, FDDI

switch

, FIBER

splitter

, FIBER

switch

, FIBERSWITCH

system

, GIGABIT

switch

,

INSERT

switch

, INSERT

unit

, LAN

switch

, MULTINET

switch

, NET

span

, PRO

line

, RESEARCH

pro

, RMON

SWITCHING

analyzer

, UNIVERSAL

switch

, and WAN

switch

are trademarks of Datacom Systems, Inc. 1

ST

in Switching

Solutions

®

, DATACOM

systems

®

, LAN

clipper

®

, MAN

Agents

®

, and MULTI

view

®

are registered trademarks of Datacom Systems,

Inc. All other registered and unregistered trademarks are the sole property of their respective owners. All specifications may be
changed without notice.

License Agreement

Notice To All Users:

For the specific terms of your license to use the software that this documentation describes, consult the

readme.1st, license.txt, or other license document that accompanies your software, either as a text file or as part of the software
packaging. If you do not agree to all of the terms set forth therein, do not install the software. If applicable, you may return the
product to the place of purchase for a full refund.

Proprietary Notice

This document contains proprietary information about the MULTINET

switch

and is not to be disclosed or used except as

authorized by written contract with Datacom Systems, Inc.

Содержание MULTINETswitch D28100BTSL

Страница 1: ... SEGMENTS MULTINETswitch D28100BTSL DATACOMsystems NETWORKS 1 2 3 4 5 6 7 8 WAN LAN LINKS SEGMENTS MULTINETswitch D2845TRSL DATACOMsystems NETWORKS MUL TINETswitch HARDWAREguide MULTINETswitch D28100BTSL Empowering Network Professionals DATACOM SYSTEMS INC ...

Страница 2: ......

Страница 3: ...i December 2001 D28100SLseries D28100BTSL D2845TRSL Part Number 541 0053 B 04 MUL TINETswitch HARDWAREguide ...

Страница 4: ... are trademarks of Datacom Systems Inc 1ST in Switching Solutions DATACOMsystems LANclipper MANAgents and MULTIview are registered trademarks of Datacom Systems Inc All other registered and unregistered trademarks are the sole property of their respective owners All specifications may be changed without notice License Agreement Notice To All Users For the specific terms of your license to use the ...

Страница 5: ...frequency energy and if not installed and used in accordance with the instruction manu al may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Certifications This equipment has been tested and found to meet the radiated a...

Страница 6: ...ral Electrical Environmental Mechanical A1 Panel Description Front Panel B1 Rear Panel B3 Daisy Chain Daisy Chain Addressing Connection Instructions C1 Hardware Installation C3 MULTIview Installation C5 Troubleshooting General No Power D1 Control Function D3 Access Function D5 Warranty Warranty Limitation On Liability E1 iv TABLE OF C CO ON NT TE EN NT TS S ...

Страница 7: ...SERguide is organized Section Appendix Contents Preface USERguide Purpose and Scope Introduction Product Overview Hardware Installation of Switch Specifications Switch Information Panel Description Front Rear Details Daisy Chain Multiple Switches Troubleshooting Solving Common Problems Warranty Our Guarantee to You Audience This USERguide is written for the person who must install and connect a MU...

Страница 8: ...stern time weekdays Customer Service is avail able via telephone facsimile and Internet E mail Outside of support hours please leave a voice message and our Customer Service Staff will return your call as soon as possible Mail Datacom Systems Inc Customer Service 9 Adler Drive East Syracuse NY 13057 1290 Tel 315 463 9541 FAX 315 463 9557 E mail support datacomsystems com World Wide Web You can obt...

Страница 9: ... many network managers you have an urgent need to monitor and analyze paths between work stations and hubs The Datacom MULTINETswitches are capable of switch ing up to two Network Devices between MULTINET segments and links The MULTINETswitch is capable of moving Sniffer Technologies Distributed Sniffer System DSS Servers transparently from one network segment or network link to another under comp...

Страница 10: ...rt of the MULTINETswitch using a DRL312 3 cable Step 2 For a MULTINETswitch to dual DSS Server con nect the COM 1 port of the DSS Server to the Control port of the MULTINETswitch using a DRL293A 3 Control Cable Step 3 Connect network cables going to each network seg ment port and link port Step 4 Connect the Power Supply 5 pin DIN Male connec tor into the Power port of the MULTINETswitch and then ...

Страница 11: ...r Sniffer Technologies LAN DSS Server DRL312 3 Common Cable Network Associates DSS SIS Analyzer Sniffer Technologies WAN DSS Server Link Control POWER LAN WAN Common 2 1 4 3 6 5 7 8 L A N WAN 1 2 3 4 5 6 7 8 Link Control POWER LAN WAN Common 2 1 4 3 6 5 7 8 L A N WAN 1 2 3 4 5 6 7 8 Network Connector Types Topology D28100 LAN Common DB15F to DB15M RJ45 to RJ45 RJ45 to RJ45 WAN Common D2845 LAN Com...

Страница 12: ...equirements Table A1 shows the MULTINET switch capacity network type network connectivity prod uct weight and shipping weight Electrical Nominal Power Requirements The MULTINETswitch has been provided with an external power supply requiring 100 240 Volts AC at 50 60 Hertz This supply is provided as a standard no charge accessory The DC voltage and current output ratings are 5 Volts DC at 4 0 Amper...

Страница 13: ...itch Specifications MULTINETswitch SWITCH CAPACITY NETWORK TYPE NETWORK ATTACHIVITY PRODUCT WEIGHT SHIPPING WEIGHT D28100BTSL 2x8 10BaseT and WAN RJ45 and DB15 12 18 D2845TRSL 2x8 4 16 Token Ring and WAN RJ45 and DB15 12 18 ...

Страница 14: ...ts follows Power Agreen light within the center of the Datacom logo indicates power is on Networks 1 through 8 A green light under a number legend indicates a completed connection has been made from that MULTINETswitch WAN link to the WAN Common Port A red light under the number legend indicates a completed connection has been made from that MULTINETswitch LAN segment to the LAN Common Port B1 PAN...

Страница 15: ...SL Front Panel Figure B2 D2845TRSL Front Panel 1 2 3 4 5 6 7 8 WAN LAN LINKS SEGMENTS MULTINETswitch D28100BTSL DATACOMsystems NETWORKS 1 2 3 4 5 6 7 8 WAN LAN LINKS SEGMENTS MULTINETswitch D2845TRSL DATACOMsystems NETWORKS ...

Страница 16: ...ort This connector port is shielded and is cabled to the LAN MONITOR port of a dual DSS Server or previous switch LAN Segment Port 8 if daisy chained The MULTINET switch connects the selected LAN segment port 1 8 to the LAN Common Port Control This connector port is a shielded DB9 Female and is cabled to the COM 1 port s of one or both connected DSS s or to the previous switch Link port if daisy c...

Страница 17: ...B4 Figure B3 D28100BTSL and D2845TRSL Rear Panel Link Control POWER LAN WAN Common 2 1 4 3 6 5 7 8 L A N WAN 1 2 3 4 5 6 7 8 ...

Страница 18: ...h the ATTACHit program as described in the DATACOMswitch SOFTWAREguide Connection Instructions The typical daisy chain addressing installation described herein will be for a D28100BTSL MULTINETswitch Step 1 Connect the COM1 port of the computer platform to the Control port of the MULTINETswitch using a DRL293A 3 cable as shown Figure C1 Step 2 Connect the Power Supply 5 pin Female connector into t...

Страница 19: ...C2 Figure C1 Connectivity for Daisy Chain Addressing DRL293A 3 Control Cable Link Control POWER LAN WAN Common 2 1 4 3 6 5 7 8 L A N WAN 1 2 3 4 5 6 7 8 Server or PC ...

Страница 20: ...RL366 3 respectively Step 2 Connect the COM1 ports of the dual DSS Server to the Control port of the first MULTINETswitch using a DRL293A 3 Control Cable Then connect the Link port of the first MULTINETswitch to the Control port of the second MULTINETswitch using a DRL293A 3 cable Step 3 Connect network cables to the desired Link and Segment ports of each MULTINETswitch Step 4 Connect the Power Su...

Страница 21: ...8 Network Associates DSS SIS Analyzer Sniffer Technologies DSS Server DRL293A 3 Control Cable HUB SniffMaster Link Control POWER LAN WAN Common 2 1 4 3 6 5 7 8 L A N WAN 1 2 3 4 5 6 7 8 DRL366 3 Common Cable DRL293A 3 Control Cable Address 0 and 1 Address 2 and 3 DRL312 3 Common Cable DRL312 3 Common Cable DRL366 3 Common Cable ...

Страница 22: ...on Port of the second Datacom LANswitch using a DRL312 3 cable Step 2 Connect network cables to the desired Network ports of each MULTINETswitch Step 3 Plug the Female end of a power cord into the recep tacle on the back of the MULTIview cabinet and the Male end of the power cord into a grounded wall receptacle that is located in close proximity to the MULTIview unit A green light within the cente...

Страница 23: ...AN 3 5 7 8 6 4 2 8 6 4 2 7 5 3 1 10 100Mb RJ 45 ACT LINK 100 DRL312 3 Common Cable DRL366 3 Common Cable DRL293A 3 Control Cable MULTIview 1 2 3 4 6 7 8 5 the switching network analyzer Daisy DATACOMsystems POWER RESET Network Segments FIBERswitch MV8200E 1 00BaseFx Full Duplex SniffMaster 1 2 3 4 5 6 7 8 1 0 1 1 1 2 1 3 1 4 1 5 1 6 9 Daisy Network Segments POWER RESET Distributed Sniffer System R...

Страница 24: ...vice D1 PROBLEM TROUBLESHOOTING SUGGESTIONS Please check the obvious Ensure that the Power Supply 5 pin DIN Male connector is inserted into position in the POWER port Check that the power cord is properly attached Verify that the external power source wall receptacle has power available Try plug ging another device into the outlet to see if it works If you have a known good power supply or power c...

Страница 25: ...D2 ...

Страница 26: ...ftware If a communications time out has occurred confirm that the proper Control Cable is in use Either a DRL293A 3 or a DRL341 3 3 Control Cable must be used because the CONTROL port is a modified RS232 that will work only with the Datacom supplied cables If the prop er cable has been used substitute a known good DRL293A 3 or a DRL341 3 3 Control Cable The DSS Analyzer from which you are trying t...

Страница 27: ...D4 ...

Страница 28: ...If the problem exhibited by that segment is the same as the suspect port the problem is the cable not the switch Disconnect a patch cable from a switch port that is functioning properly and reconnect it to the suspect port If the suspect port still fails the problem is in the switch Contact Datacom Systems Inc Customer Service IMPORTANT The distance parameters of Ethernet and Token Ring must be ad...

Страница 29: ...k Connector Types Topology D28100 LAN Common DB15F to DB15M RJ45 to RJ45 RJ45 to RJ45 WAN Common D2845 LAN Common Table F1 Switch Connector Cable Information Common Cable DRL312 3 DRL298 3 DRL296A 3 or DRL366 3 ...

Страница 30: ... NUMBER FROM DATACOM CUSTOMER SERVICE AT 315 463 9541 ITEMS WITHOUT AN RMA WILL BE REFUSED OR RETURNED FREIGHT COLLECT DSI shall have no responsibility for any deficiency resulting from accidents misuse modifications power disturbances e g lighten ing ESD use of a power supply not specified by DSI etc or var ious other forms of disaster e g earthquakes floods etc If returned equipment is found to ...

Страница 31: ...E2 ...

Страница 32: ...N NO OT TE ES S ...

Страница 33: ......

Страница 34: ... 1x8 ATM OC12 multimode Dual SC A83M 1x8 ATM OC3 multimode Dual SC A412S 1x4 ATM OC12 single mode Dual SC A43S 1x4 ATM OC3 single mode Dual SC F83M 1x8 100BaseFX multimode Dual SC F83M SP 1x8 100BaseFX multimode Dual SC FIBERsplitter MODEL TAPS TOPOLOGY CONNECTIVITY FS4MSL 4 100FX OC3 OC12 Gigabit Dual SC FS4SSL 4 OC3 OC12 Gigabit Dual SC FS8MSL 8 100FX OC3 OC12 Gigabit Dual SC FS8SSL 8 OC3 OC12 G...

Страница 35: ......

Страница 36: ...Datacom Systems Inc 9 Adler Drive East Syracuse New York 13057 TEL 315 463 9541 FAX 315 463 9557 http www datacomsystems com Empowering Network Professionals DATACOM SYSTEMS INC ...

Отзывы: