7. Firmware Upgrade
From time to time Datavideo may release new firmware to either add new SE-1200 MU
features or to fix user reported bugs in the current switcher firmware. Customers can
update the switcher firmware themselves if they wish, or they can contact their local
supplier or Datavideo office for assistance, should they prefer this method.
This page describes the firmware update process, and it should take
approximately few
minutes total time to complete
.
Once started
the update process should not be interrupted in any way
as this could result
in a non-responsive unit.
1.
Format the USB drive to FAT32.
2.
Copy image file RMC400.bin to the formatted USB drive.
3.
Locate the FW Upgrade USB port on the back panel of the RMC-400.
4.
While power OFF, insert the USB drive into the “
FW Upgrade
” USB port.
5.
Switch the power ON and the RMC-400 will start the firmware upgrade automatically.
6.
If the upgrade is successful, all panel buttons will turn green and then remove the USB
drive from the FW Upgrade USB port.
Note: If the upgrade failed, all buttons will start flashing red.