FACTORY DEFAULTS

Default Values

Customer Values

Serial Number

n/a

Version

n/a

Sensor Type

Pulse

K=

1

offset=

0

Flow Rate Units

gpm

Alarm Type

off

High Alarm Latched

off

High Alarm Set Point

120

High Alarm Set Point Delay

5

High Alarm Release Point

110

High Alarm Release Point Delay

10

Low Alarm Latched

off

Low Alarm Set Point

10

Low Alarm Set Point Delay

5

Low Alarm Release Point

15

Low Alarm Release Point Delay

10

Filter Coeff

2

Содержание 330

Страница 1: ...erminals The unit should be protected from weather and moisture in accordance with electrical codes and standard trade practices In any mounting arrangement the primary concerns are ease of wiring and attachment of the programming cable The unit generates very little heat so no consideration need be given to cooling or ventilation Surface Mount Installation The Model 330 may be mounted to the surf...

Страница 2: ...abeled beside the header Observe the polarity shown on the label If a Data Industrial plug in type power supply A 1026 or A 503 is used connect the black white striped wire to the terminal marked positive and the black wire to the terminal marked negative Note Included with every Model 330 is a 330IK kit containing a screw lock washer and ground lead to connect the Model 330 to Earth Ground This w...

Страница 3: ...the Model 330 If sensor is a Non Data Industrial Flow Sensor The Sensor Input Power terminal supplies nominal 9 1VDC excitation voltage for 3 wire sensors Connect sensor signal and sensor signal wires to transmitter terminals Relay Output Wiring The Model 330 is supplied with a removable DPST relay with normally open and normally closed contacts To wire to the normally closed contacts connect to t...

Страница 4: ...der to program the Model 330 must be connected to power and the A301 cable must be connected to the Model 330 Comm port connector and an available 9 pin COM port on a computer Note The Data Industrial A301 Cable will work with all 300 Series products However the older version of the cable A300 does not have sufficient bandwidth to work with the 340 Series Transmitters Data Industrial provides free...

Страница 5: ...01 communications cable to the socket labeled D I C Comm Port taking care to properly align the tab on the plug and socket to maintain polarity Connect the DB9 connector of the Data Industrial A301 communications cable to a PC com port that has the Model 330 software installed 3 Connect the Model 330 transmitter to a power supply 4 Open the interface software and select the appropriate COM PORT as...

Страница 6: ...nterrupt all timing functions and return them to the initial programmed settings and or de energize the relay coil that has been latched as a result of an alarm function This reset may be accomplished by momentarily disconnecting the power supply or connecting an external device to the reset terminals Filter Coefficient An averaging routine that smooths out unstable flow The non linear reference s...

Страница 7: ...between flow point and relay actuation Transient Suppression Designed to withstand a 5000 volt 1 2 micro second 100KHz ring wave SENSOR CALIBRATION Data Industrial Use K and offset provided in sensor owner s manual Other Sensors Check with factory UNITS OF MEASURE Flow measurement Rate gpm gph l sec l min l hr ft3 sec ft3 min ft3 hr m3 sec m3 min m3 hr PROGRAMMING Requires PC or laptop running Win...

Страница 8: ...se K 1 offset 0 Flow Rate Units gpm Alarm Type off High Alarm Latched off High Alarm Set Point 120 High Alarm Set Point Delay 5 High Alarm Release Point 110 High Alarm Release Point Delay 10 Low Alarm Latched off Low Alarm Set Point 10 Low Alarm Set Point Delay 5 Low Alarm Release Point 15 Low Alarm Release Point Delay 10 Filter Coeff 2 ...

Страница 9: ...ler may at its sole option instruct Buyer to ship subject part postage prepaid to the Seller at above address or authorize a representative to inspect the part on site Seller will at its sole option repair or replace any defective product covered by this warranty If Buyer makes repairs or alterations to any product or part covered by this warranty without Sellers prior written approval this warran...

Отзывы: